ASDXRRX001PDAA5 Honeywell, ASDXRRX001PDAA5 Datasheet - Page 2

Board Mount Pressure Sensors Differential 0 psi to 1.0 psi

ASDXRRX001PDAA5

Manufacturer Part Number
ASDXRRX001PDAA5
Description
Board Mount Pressure Sensors Differential 0 psi to 1.0 psi
Manufacturer
Honeywell

Specifications of ASDXRRX001PDAA5

Operating Pressure
0 psi to 5 psi
Pressure Type
Differential
Accuracy
+/- 2 %
Output Type
Digital
Mounting Style
DIP
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 20 C
Operating Supply Voltage
5 V
Supply Voltage (min)
4.75 V
Supply Voltage (max)
5.25 V
Supply Current
2.5 mA
Package / Case
DIP-8
Body Style
Rectangular
Function
Pressure
Mounting Type
PCB
Primary Type
Pressure
Range, Measurement
1 PSID
Sensing Mode
Differential
Technology
Piezoelectric
Voltage, Supply
3.3-5 VDC
Wide Compensated Temperature Range
0°C to+ 85°C (+32°F to +185°F)
Pressure Ranges
From 0 psi to 1 psi through 0 psi to 30 psi
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
ASDX Series
TABLE 1. GENERAL SPECIFICATIONS
Note:
1. The sensor is not reverse polarity protected. Incorrect application of excitation voltage or ground to the wrong pin can cause electrical failure. Application of supply
TABLE 2. PRESSURE RANGE SPECIFICATIONS
Note:
1. If the maximum burst pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing die may fracture.
TABLE 3. PERFORMANCE SPECIFICATIONS
Notes:
1. Reference conditions (unless otherwise noted): Supply voltage, V
2. Span is the algebraic difference between the output voltage at the specified pressure and the output at zero pressure. Span is ratiometric to the supply voltage.
3. Accuracy is the combined errors from offset and span calibration, linearity, pressure hysteresis, and temperature effects. Linearity is the measured deviation based on
4. Response time for a 0 psi to full-scale pressure step change, 10% to 90% rise time.
5. The smallest change in the output voltage, given any change in pressure.
FIGURE 1. BLOCK DIAGRAM
Note:
1. 220 nF capacitor is required between +Vs and GND. 15 nF capacitor between Vout and ground is optional.
2
Supply voltage (Vs)
Maximum supply voltage
Consumption current
Output current (sink)
Output current (source)
Lead temperature
Compensated temp. range
Operating temp. range
Storage temp. range
Vibration
Shock
Life
Catalog Listing
ASDX001
ASDX005
ASDX015
ASDX030
ASDX100
Characteristic
Zero pressure offset
Full scale span
Output at FS pressure
Accuracy
Response time
Quantization step
voltage above the maximum can cause electrical failure.
a straight line. Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. Calibration
errors include the deviation of offset and full scale from nominal values.
www.honeywell.com/sensing
(1)
(1)
Symbol
Vfss
Vfso
Voff
Pressure Range
0 psi to 100 psi
0 psi to 15 psi
0 psi to 30 psi
0 psi to 1 psi
0 psi to 5 psi
(1)
4.75 Vdc to 5.25 Vdc
6.50 Vdc (max.)
6 mA (typ.)
2 mA (max.)
2 mA (max.)
2 s to 4 s at 250 °C [482 °F]
0 °C to 85 °C [32 °F to 185 °F]
-20 °C to 105 °C [-4 °F to 221 °F]
-40 °C to 125 °C [-40 °F to 257 °F]
10 g at 20 Hz to 2000 Hz
100 g for 11 ms
1 million cycles minimum
S
0.420
4.420
=5.0 ±0.01 Vdc; T
Min.
A
=25 °C [77 °F]. Output is ratiometric within the supply voltage range (Vs).
0.500
4.500
Typ.
4.00
8
3
Burst Pressure
150 psi
20 psi
30 psi
60 psi
5 psi
0.580
4.580
Max.
±2.0
(1)
Unit
Vdc
Vdc
Vdc
%V
mV
ms
Sensitivity
0.267 V/psi
0.133 V/psi
0.040 V/psi
4.00 V/psi
0.80 V/psi
Note
2
3
4
5

Related parts for ASDXRRX001PDAA5