MMA7660FCR1 Freescale Semiconductor, MMA7660FCR1 Datasheet - Page 19

Board Mount Accelerometers 3-Axis Digital Out Accelerometer

MMA7660FCR1

Manufacturer Part Number
MMA7660FCR1
Description
Board Mount Accelerometers 3-Axis Digital Out Accelerometer
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MMA7660FCR1

Sensing Axis
X, Y, Z
Acceleration
1.5 g
Digital Output - Number Of Bits
6 bit
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Digital Output - Bus Interface
12 C
Sensitivity
21.33 count/g
Package / Case
DFN-10
Output Type
Digital
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MMA7660FCR1
Manufacturer:
FREESCAL
Quantity:
5 962
Part Number:
MMA7660FCR1
Quantity:
7 000
Part Number:
MMA7660FCR1
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MMA7660FCR1
0
Company:
Part Number:
MMA7660FCR1
Quantity:
512
Company:
Part Number:
MMA7660FCR1
Quantity:
324
Sensors
Freescale Semiconductor
AMSR[2:0]
000
001
010
011
100
101
110
111
NAME
AMPD
AM64
AM32
AM16
AM8
AM4
AM2
AM1
Tap Detection Mode and 120 Samples/Second Active and Auto-Sleep Mode
Tap Detection Sampling Rate: The device takes readings continually at a rate of nominally 3846 g-cell
measurements a second. It then filters these high speed measurements by maintaining continuous rolling averages of
the current and last g-cell measurements. The averages are updated every 260 µs to track fast moving accelerations.
Tap detection: itself compares the two filtered axis responses (fast and slow) described above for each axis. The
absolute (unsigned) difference between the fast and slow axis responses is compared against the tap detection delta
threshold value PDTH[4:0] in the PDET (0x09) register.
For portrait/landscape detection: The device takes and averages 32 g-cell measurements every 8.36 ms in Active
Mode and Auto-Sleep. The update rate is 120 samples per second. These measurements update the XOUT (0x00),
YOUT (0x01), and ZOUT (0x02) registers also.
64 Samples/Second Active and Auto-Sleep Mode
For portrait/landscape detection: The device takes and averages 32 g-cell measurements every
15.625 ms in Active Mode and Auto-Sleep. The update rate is 64 samples per second. These measurements update
the XOUT (0x00), YOUT (0x01), and ZOUT (0x02) registers also.
32 Samples/Second Active and Auto-Sleep Mode
For portrait/landscape detection: The device takes and averages 32 g-cell measurements every 31.25 ms in Active
Mode and Auto-Sleep. The update rate is 32 samples per second. These measurements update XOUT (0x00), YOUT
(0x01), and ZOUT (0x02) registers also.
16 Samples/Second Active and Auto-Sleep Mode
For portrait/landscape detection: The device takes and averages 32 g-cell measurements every 62.5 ms in Active
Mode and Auto-Sleep. The update rate is 16 samples per second. These measurements update the XOUT (0x00),
YOUT (0x01), and ZOUT (0x02) registers also.
8 Samples/Second Active and Auto-Sleep Mode
For portrait/landscape detection: The device takes and averages 32 g-cell measurements every 125 ms in Active
Mode and Auto-Sleep. The update rate is 8 samples per second. These measurements update the XOUT (0x00),
YOUT (0x01), and ZOUT (0x02) registers also.
4 Samples/Second Active and Auto-Sleep Mode
For portrait/landscape detection: The device takes and averages 32 g-cell measurements every 250 ms in Active
Mode and Auto-Sleep. The update rate is 4 samples per second. These measurements update the XOUT (0x00),
YOUT (0x01), and ZOUT (0x02) registers also.
2 Samples/Second Active and Auto-Sleep Mode
For portrait/landscape detection: The device takes and averages 32 g-cell measurements every 500 ms in Active
Mode and Auto-Sleep. The update rate is 2 samples per second. These measurements update the XOUT (0x00),
YOUT (0x01), and ZOUT (0x02) registers also.
1 Sample/Second Active and Auto-Sleep Mode
For portrait/landscape detection: The device takes and averages 32 g-cell measurements every 1000 ms in Active
Mode and Auto-Sleep. The update rate is 1 sample per second. These measurements update the XOUT (0x00), YOUT
(0x01), and ZOUT (0x02) registers also.
DESCRIPTION
MMA7660FC
19