MAX5974DETE+ Maxim Integrated Products, MAX5974DETE+ Datasheet - Page 12

Current Mode PWM Controllers ACTIVE-CLAMPED CUR MODE PWM CONTLR

MAX5974DETE+

Manufacturer Part Number
MAX5974DETE+
Description
Current Mode PWM Controllers ACTIVE-CLAMPED CUR MODE PWM CONTLR
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX5974DETE+

Duty Cycle (max)
82 %
Mounting Style
SMD/SMT
Switching Frequency
600 KHz
Operating Supply Voltage
12 V to 21 V
Supply Current
1.8 mA
Maximum Operating Temperature
+ 85 C
Fall Time
14 ns
Minimum Operating Temperature
- 40 C
Rise Time
27 ns
Package / Case
TQFN-16
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Active-Clamped, Spread-Spectrum,
Current-Mode PWM Controllers
12
PIN
10
11
12
13
14
15
16
6
7
8
9
AUXDRV
DCLMP
NAME
PGND
NDRV
CSSC
GND
CS
EN
FB
SS
EP
IN
Transconductance Amplifier Inverting Input
Signal Ground
Current Sense with Slope Compensation Input. A resistor connected from CSSC to CS programs the
amount of slope compensation. See the Programmable Slope Compensation section.
Current-Sense Input. Current-sense connection for average current sense and cycle-by-cycle cur-
rent limit. Peak current-limit trip voltage is 400mV and reverse current-limit trip voltage is -100mV.
Power Ground. PGND is the return path for gate-driver switching currents.
Main Switch Gate-Driver Output
pMOS Active Clamp Switch Gate-Driver Output. AUXDRV can also be used to drive a pulse trans-
former for synchronous flyback application.
Converter Supply Input. IN has wide UVLO hysteresis, enabling the design of efficient power sup-
plies. When the enable input EN is used to program a UVLO level for the power source, connect a
zener diode between IN and PGND to ensure that V
mum rating of 26V.
Enable Input. The gate drivers are disabled and the device is in a low-power UVLO mode when the
voltage on EN is below V
enable conditions. See the Enable Input section for more information about interfacing to EN.
Feed-Forward Maximum Duty-Cycle Clamp Programming Input. Connect a resistive divider between
the input supply voltage DCLMP and GND. The voltage at DCLMP sets the maximum duty cycle
(D
remains protected during line transients.
Soft-Start Programming Capacitor Connection. Connect a capacitor from SS to GND to program the
soft-start period. This capacitor also determines hiccup mode current-limit restart time. A resistor
from SS to GND can also be used to set the D
Exposed Pad. Internally connected to GND. Connect to a large ground plane to maximize thermal
performance. Not intended as an electrical connection point.
MAX
) of the converter inversely proportional to the input supply voltage, so that the MOSFET
ENF
. When the voltage on EN is above V
FUNCTION
MAX
below 75%.
IN
Pin Description (continued)
is always clamped below its absolute maxi-
ENR
, the device checks for other

Related parts for MAX5974DETE+