ZMOT0BSB0A0BG Zilog, ZMOT0BSB0A0BG Datasheet - Page 32

Microcontrollers (MCU) ZMB N. SDA02-54-P Py Fr AA 0.9 GI T1 Lens

ZMOT0BSB0A0BG

Manufacturer Part Number
ZMOT0BSB0A0BG
Description
Microcontrollers (MCU) ZMB N. SDA02-54-P Py Fr AA 0.9 GI T1 Lens
Manufacturer
Zilog
Datasheet

Specifications of ZMOT0BSB0A0BG

Processor Series
ZMOTION
Core
Z8FS040
Number Of Timers
2
Operating Supply Voltage
2.7 V to 3.6 V
Maximum Operating Temperature
+ 105 C
Mounting Style
SMD/SMT
Program Memory Type
Flash
Program Memory Size
4 KB
Package / Case
SOIC-8
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ZMOT0BSB0A0BG
Manufacturer:
Zilog
Quantity:
3
PS028510-0111
PIR Stable (Bit 0)
Bit
Field
Control
Address
Engine Timer Tick (Bit 7)
Passive Infrared (PIR) sensor signal stabilized bit; controlled by the PIR engine.
After periods of non-use the PIR sensor will take some time to stabilize before it can be used reliably.
The amount of time is dependant on the PIR Sensor being used and environmental conditions and can
range from a few seconds up to a minute. To relieve the application software from having to assume
the worst case stabilization time, the PIR engine automatically monitors the DC offset of the PIR sensor
and sets this bit when it determines that it has become stable. This bit indicates that the PIR sensor has
stabilized after one of the following conditions:
• After initial power on (cold start).
• After re-enabling the Engine via PIR Enable Register.
• After returning from sleep mode.
PIR One Second Timer Tick
Set by the application; cleared by the PIR engine.
• This bit must be set to 1 one time per second by the user application to provide the engine with a one-
second tick to perform housekeeping operations relating to motion de tection. The engine will routinely
poll this bit to obtain a one-second tick. This bit is cleared by the engine.
0 = PIR sensor signal is not stable, motion detected events are not valid.
1 = PIR sensor signal is stable, motion detected events are valid.
0 = Cleared by the PIR engine.
1 = A one-second interval has occurred.
Timer Tick
Engine
R/W
7
Table 10. PIR Status/Control Register 1 (ePIR_SC1)
6
Frequency Response
5
Read/Write
4
ZMOTION™ Detection and Control Family
103H
3
PIR Scan
Rate
R/W
2
Product Specification
Standard API Register Set
Reserved Dual Pyro
1
0
Enable
R/W
0
25