GLS29EE512-70-4I-NHE Greenliant, GLS29EE512-70-4I-NHE Datasheet - Page 4

EEPROM 64K X 8 70ns

GLS29EE512-70-4I-NHE

Manufacturer Part Number
GLS29EE512-70-4I-NHE
Description
EEPROM 64K X 8 70ns
Manufacturer
Greenliant
Datasheet

Specifications of GLS29EE512-70-4I-NHE

Organization
64 K x 8
Interface Type
Parallel
Access Time
70 ns
Output Enable Access Time
30 ns
Supply Voltage (max)
5.5 V
Supply Voltage (min)
4.5 V
Maximum Operating Current
20 mA
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
4.5 V, 5.5 V
Memory Size
512 Kbit
Package / Case
PLCC-32
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
GLS29EE512-70-4I-NHE
Manufacturer:
Greenlia
Quantity:
54
Data Sheet
Single power supply reprogrammable nonvolatile memo-
ries may be unintentionally altered. Greenliant strongly rec-
ommends that Software Data Protection (SDP) always be
enabled. The GLS29EE512 should be programmed using
the SDP command sequence. Greenliant recommends the
SDP Disable Command Sequence not be issued to the
device prior to writing.
Please refer to the following Application Notes for more
information on using SDP:
Product Identification
The Product Identification mode identifies the device as the
GLS29EE512 and manufacturer as Greenliant. This mode
is accessed via software. For details, see Table 4, Figure
11 for the software ID entry, and Read timing diagram and
Figure 18 for the ID entry command sequence flowchart.
©2010 Greenliant Systems, Ltd.
F
UNCTIONAL
Protecting Against Unintentional Writes When
Using Single Power Supply Flash Memories
The Proper Use of JEDEC Standard Software
Data Protection
A 15 - A 0
B
WE#
OE#
LOCK
CE#
D
IAGRAM
Address Buffer & Latches
Control Logic
X-Decoder
4
TABLE 1: P
Product Identification Mode Exit
In order to return to the standard Read mode, the Software
Product Identification mode must be exited. Exiting is
accomplished by issuing the Software ID Exit (reset) opera-
tion, which returns the device to the Read operation. The
Reset operation may also be used to reset the device to
the Read mode after an inadvertent transient condition that
apparently causes the device to behave abnormally, e.g.,
not read correctly. See Table 4 for software command
codes, Figure 12 for timing waveform, and Figure 18 for a
flowchart.
Manufacturer’s ID
Device ID
512 Kbit Page-Write EEPROM
GLS29EE512
Y-Decoder and Page Latches
I/O Buffers and Data Latches
RODUCT
DQ 7 - DQ 0
SuperFlash
Memory
I
DENTIFICATION
Address
0000H
0001H
S71060-10-000
GLS29EE512
1060 B1.1
Data
BFH
5DH
T1.3 1060
05/10