M24C16-WMN6TP STMicroelectronics, M24C16-WMN6TP Datasheet - Page 17

EEPROM EEPROM S I2C 16k

M24C16-WMN6TP

Manufacturer Part Number
M24C16-WMN6TP
Description
EEPROM EEPROM S I2C 16k
Manufacturer
STMicroelectronics
Datasheet

Specifications of M24C16-WMN6TP

Organization
2 K x 8
Interface Type
I2C
Maximum Clock Frequency
0.4 MHz
Access Time
900 ns
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.5 V
Maximum Operating Current
2 mA
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
3.3 V, 5 V
Memory Size
16 Kbit
Package / Case
SOIC-8 Narrow
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M24C16-WMN6TP
Manufacturer:
TI
Quantity:
5 600
Part Number:
M24C16-WMN6TP
Manufacturer:
ST
Quantity:
1 000
Part Number:
M24C16-WMN6TP
Manufacturer:
ST
Quantity:
1 000
Part Number:
M24C16-WMN6TP
Manufacturer:
ST
Quantity:
1 399
Part Number:
M24C16-WMN6TP
Manufacturer:
ST
Quantity:
8 000
Part Number:
M24C16-WMN6TP
Manufacturer:
ST
Quantity:
256
Part Number:
M24C16-WMN6TP
Manufacturer:
ST
Quantity:
20 000
Part Number:
M24C16-WMN6TP
0
Company:
Part Number:
M24C16-WMN6TP
Quantity:
10 000
Company:
Part Number:
M24C16-WMN6TP
Quantity:
1 863
Part Number:
M24C16-WMN6TP (24C16WP)
Manufacturer:
ST
0
Part Number:
M24C16-WMN6TP/P
Manufacturer:
ST
Quantity:
20 000
M24C16, M24C08, M24C04, M24C02, M24C01
3.7.2
3.7.3
3.7.4
Current Address Read
For the Current Address Read operation, following a Start condition, the bus master only
sends a device select code with the Read/Write bit (RW) set to 1. The device acknowledges
this, and outputs the byte addressed by the internal address counter. The counter is then
incremented. The bus master terminates the transfer with a Stop condition, as shown in
Figure
Sequential Read
This operation can be used after a Current Address Read or a Random Address Read. The
bus master does acknowledge the data byte output, and sends additional clock pulses so
that the device continues to output the next byte in sequence. To terminate the stream of
bytes, the bus master must not acknowledge the last byte, and must generate a Stop
condition, as shown in
The output data comes from consecutive addresses, with the internal address counter
automatically incremented after each byte output. After the last memory address, the
address counter ‘rolls-over’, and the device continues to output data from memory address
00h.
Acknowledge in Read mode
For all Read commands, the device waits, after each byte read, for an acknowledgment
during the 9
time, the device terminates the data transfer and switches to its Standby mode.
10, without acknowledging the byte.
th
bit time. If the bus master does not drive Serial Data (SDA) Low during this
Figure
10.
Doc ID 5067 Rev 16
Device operation
17/39

Related parts for M24C16-WMN6TP