ACST1235-7G STMicroelectronics, ACST1235-7G Datasheet

Triacs AC Switch 12A A.S.D. Igt

ACST1235-7G

Manufacturer Part Number
ACST1235-7G
Description
Triacs AC Switch 12A A.S.D. Igt
Manufacturer
STMicroelectronics
Datasheet

Specifications of ACST1235-7G

Rated Repetitive Off-state Voltage Vdrm
700 V
On-state Rms Current (it Rms)
12 A
Gate Trigger Voltage (vgt)
1 V
Gate Trigger Current (igt)
35 mA
Holding Current (ih Max)
50 mA
Mounting Style
SMD/SMT
Package / Case
D2PAK
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACST1235-7G
Manufacturer:
ST
0
Part Number:
ACST1235-7GTR
Manufacturer:
ST
0
Part Number:
ACST1235-7G������
Manufacturer:
ST
0
Features
Benefits
Applications
Description
The ACST12 series belongs to the ACS™/ACST
power switch family built with A.S.D.
specific discrete) technology. This high
performance device is suited to home appliances
or industrial systems and drives loads up to 12 A.
This ACST12 switch embeds a Triac structure and
a high voltage clamping device able to absorb the
inductive turn-off energy and withstand line
transients such as those described in the
IEC 61000-4-5 standard. The ACST1210-7 needs
a low gate current to be activated (I
and still provides a high electrical noise immunity
complying with the IEC 61000-4-4 standard. The
ACST1235-7 offers an extremely high static dV/dt
immunity of 2 kV/µs minimum.
July 2010
Triac with overvoltage crowbar technology
Low I
(I
High noise immunity: static dV/dt > 2000 V/µs
Enables equipment to meet IEC 61000-4-5
High off-state reliability with planar technology
Need no external over voltage protection
Reduces the power passive component count
High immunity against fast transients
described in IEC 61000-4-4 standards
AC mains static switching in appliance and
industrial control systems
Drive of medium power AC loads such as:
– Universal motor of washing machine drum
– Compressor for fridge or air conditioner
GT
<35 mA) version
GT
(<10 mA) or high immunity
GT
®
(application
< 10 mA)
Doc ID 15238 Rev 3
Overvoltage protected AC switch
Figure 1.
Table 1.
TM: ACS is a trademark of STMicroelectronics
®: A.S.D. is a registered trademark of STMicroelectronics
OUT
V
DRM
Symbol
I
T(RMS)
ACST1210-7T
ACST1235-7T
I
GT
TO-220AB
/V
RRM
Functional diagram
Device summary
G
COM
OUT
10 or 35
G
Value
700
12
COM
OUT
OUT
ACST1210-7G
ACST1235-7G
ACST12
D
2
PAK
COM
Unit
mA
A
V
www.st.com
G
1/13
13

Related parts for ACST1235-7G

ACST1235-7G Summary of contents

Page 1

... I (application T(RMS DRM RRM I GT < 10 mA) GT TM: ACS is a trademark of STMicroelectronics ®: A.S. registered trademark of STMicroelectronics Doc ID 15238 Rev 3 ACST12 OUT G OUT COM COM 2 D PAK ACST1210-7G ACST1235-7G Functional diagram OUT G COM Device summary Value Unit 12 A 700 www.st.com G 1/13 13 ...

Page 2

... Value Unit T = 104 ° amb 2 ° 16.7 ms 126 20.0 ms 120 125 °C 100 A/µ 125 ° 125 °C 0 125 ° 125 °C 1 150 - 125 260 Value Unit ACST1210-7 ACST1235-7 Unit 10 35 1.0 0 200 2000 V/µs 5.3 A/ms 14 850 °C °C ° ...

Page 3

ACST12 Table 4. Static characteristics Symbol ( 500 µs TM OUT p (1) V Threshold voltage T0 (1) R Dynamic resistance d I DRM OUT DRM RRM I ...

Page 4

Characteristics Figure 6. On-state characteristics (maximum values) I (A) TM 1000 100 10 T =125 °C T =25 ° Figure 8. Non repetitive surge peak on-state current for a sinusoidal pulse and corresponding ...

Page 5

ACST12 Figure 12. Relative variation of critical rate of decrease of main current versus junction temperature (dI/dt)c (dI/dt)c[T j =125° Figure 14. ...

Page 6

Application information 2 Application information 2.1 Typical application description The ACST12 device has been designed to control medium power load, such as AC motors in home appliances. Thanks to its thermal and turn off commutation performances, the ACST12 switch is ...

Page 7

... Figure 17. Universal drum motor control – typical diagram 2.2 AC line transient voltage ruggedness In comparison with standard Triacs, which are not robust against surge voltage, the ACST12 is self-protected against over-voltage, specified by the new parameter V switch can safely withstand AC line transient voltages either by clamping the low energy spikes, such as the inductive spikes at switch off switching to the on state (for less than 10 ms) to dissipate higher energy shocks through the load ...

Page 8

Application information Figure 18. Overvoltage ruggedness test circuit for resistive and inductive loads for IEC 61000-4-5 standards Filtering unit AC Mains Figure 19. Typical voltage and current waveforms across the ACST12 during IEC 61000-4-5 standard test 8/ ...

Page 9

ACST12 3 Ordering information scheme Figure 20. Ordering information scheme AC switch Topology T = Triac On-state rms current Sensitivity Voltage 7 = 700 V Package G = ...

Page 10

Package information 4 Package information ● Epoxy meets UL94, V0 ● Recommended torque (TO-220AB): 0.4 to 0.6 N·m In order to meet environmental requirements, ST offers these devices in different grades of ® ECOPACK packages, depending on their level of ...

Page 11

ACST12 2 Table 7. D PAK dimensions Figure 21. Footprint (dimensions in mm) Ref 2mm min. ...

Page 12

... Ordering information 5 Ordering information Table 8. Ordering information Order code ACST1210-7T ACST1210-7G ACST1210-7GTR ACST1235-7T ACST1235-7G ACST1235-7GTR 6 Revision history Table 9. Document revision history Date 02-Dec-2008 13-Apr-2010 01-Jul-2010 12/13 Marking Package TO-220AB 2 ACST12107 D PAK 2 D PAK TO-220AB 2 ACST12357 D PAK 2 D PAK Revision 1 First issue. ...

Page 13

... ACST12 Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notice. All ST products are sold pursuant to ST’s terms and conditions of sale. ...

Related keywords