FS24D10-06 TELEDYNE, FS24D10-06 Datasheet

Solid State Relays 10A 280 VAC Zero Cross Faston

FS24D10-06

Manufacturer Part Number
FS24D10-06
Description
Solid State Relays 10A 280 VAC Zero Cross Faston
Manufacturer
TELEDYNE
Datasheet

Specifications of FS24D10-06

Control Voltage Range
4 VDC to 30 VDC
Load Voltage Rating
280 VAC
Load Current Rating
10 A
Output Device
Triac
Mounting Style
Faston/PCB
Relay Type
DC Solid State
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FS24D10-06
Manufacturer:
Teledyne Relays
Quantity:
135
© 2010 TELEDYNE RELAYS
Part Number
FS24R10-06
FS24D10-06
FS24D10
Part Number Explanation
NOTES
1) Line Voltage (nominal): 24 = 240 Vac
2) Switch Type: R = Random turn-on; D = Zero-cross turn-on;
3) Feature: -06 = Faston terminals
.83 (21)
Figure 1a — FS relays except FS24D10 & FS24D20
.83 (21)
FS24D20-06
FS24D20
.08 (2)
.08 (2)
FS
(8.6)
.2 (5.06)
.34
(4.8x0.8)
.19x.03
MECHANICAL SPECIFICATION
Ø 0.5 (1.32)
1.18 (30)
1.4 (35.5)
.5 (12.7)
.83 (21)
24
1.4 (35.5)
1.18 (30)
.5 (12.7)
.83 (21)
Figure 1b — FS24D10 & FS24D20
(6.35x0.8)
.25x.03
20A, 280 Vac
20A, 280 Vac
Description
10A, 280 Vac
10A, 280 Vac
10A, 280 Vac
(10)
R
.39
.16 (4)
.16 (4)
.98 (25)
.83 (21)
WEIGHT: 3.2 oz. (90g)
.3 (7.62)
.32 (8)
WEIGHT: 3.2 oz. (90g)
.24 (6)
10
.46 (11.6)
(800) 284-7007 • www.teledynerelays.com
-06
.25 (6.4)
.59 (15)
.59 (15)
FEATURES/BENEFITS
• Miniature size package
• Designed for medium-power applications
• Faston or PCB terminals available
• Tight zero-cross window for low EMI
• Excellent thermal performance
• High immunity to surges
DESCRIPTION
The Series FS relays are designed for medium-power
loads. The design incorporates a triac output. The
Series FS relays utilize optical isolation to protect the
control from load transients. The FS compact
package is available with faston or PCB terminals.
Its compact size makes it ideal for designs where
space is limited. The Series FS relays have excellent
thermal performance.
APPLICATIONS
• Heating control
• Motor control
• Uninterruptible power supplies
• Light dimmers
• Industrial and process control
• On/Off controls of medium-power AC equipment
• Electromechanical line relay replacement
APPROVALS
All models are UL recognized.
UL File Number E128555.
3 +
4 –
R
EQUIVALENT CIRCUIT
Figure 2 — FS relays
Output to 20A 280 Vac
CROSS
ZERO
Series FS
DC Control
2 ~
1 ~
FS\032010\Q1
FS 1

Related parts for FS24D10-06

FS24D10-06 Summary of contents

Page 1

... Part Number Description FS24R10-06 10A, 280 Vac FS24D10-06 10A, 280 Vac FS24D10 10A, 280 Vac FS24D20 20A, 280 Vac FS24D20-06 20A, 280 Vac Part Number Explanation NOTES 1) Line Voltage (nominal 240 Vac 2) Switch Type Random turn-on Zero-cross turn-on; 3) Feature: -06 = Faston terminals MECHANICAL SPECIFICATION ...

Page 2

... Operating Frequency Range 200 A All relays for Match Fusing (<8.3ms) 1.3 V 10A output current 20A output current Series Control Voltage (V) Min Max Units Vac 3 mA 0.1 ms 8.3 ms 8.3 ms 500 V/µs 50 A/µs 0.1 440 Hz .005 .005 200 A S © 2010 TELEDYNE RELAYS FS\032010\Q1 ...

Page 3

... Figure 4b — All 20A relays output current THERMAL CHARACTERISTICS Ambient Temperature (° 100 110 120 125 Ambient Temperature (°C) Figure 5b — All 20A FS relays output current (800) 284-7007 • www.teledynerelays.com Series FS SURGE CURRENT Non-Repetitive 0 (s) 10 100 1000 Number of Cycles 100 110 120 125 FS\032010\ ...

Related keywords