G3NA-225B-AC100-120 Omron, G3NA-225B-AC100-120 Datasheet - Page 4

Solid State Relays 100-120VA/240VAC 25A

G3NA-225B-AC100-120

Manufacturer Part Number
G3NA-225B-AC100-120
Description
Solid State Relays 100-120VA/240VAC 25A
Manufacturer
Omron

Specifications of G3NA-225B-AC100-120

Control Voltage Range
100 VAC to 120 VAC
Load Voltage Rating
240 V
Off State Leakage Current (max)
5 mA, 10 mA
Load Current Rating
25 A
Contact Form
1 Form A
Output Device
Triac
Input To Output Isolation Method
Photocoupler
Relay Type
General Purpose Hockey Puck
Termination Style
Screw
Operating Voltage Range
19VAC To 264VAC
Load Current
25A
Isolation Voltage
2500VAC
Control Voltage Type
AC
Relay Terminals
Screw
Load Voltage Min
24VAC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G3NA-225B-AC100-120
Manufacturer:
Omron Electronics
Quantity:
135
Specifications
■ Ratings
Input (at an Ambient Temperature of 25°C)
Note: 1. The input impedance is measured at the maximum value of the rated supply voltage (for example, with the model rated at 100 to 120 VAC,
Output
Note: 1. The load current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature under Engineering Data
G3NA-2@@B
G3NA-4@@B
G3NA-D210B
G3NA-275B-UTU(-2)
G3NA-290B-UTU(-2)
G3NA-475B-UTU(-2)
G3NA-490B-UTU(-2)
G3NA-205B
G3NA-210B
G3NA-220B
G3NA-240B
G3NA-410B
G3NA-420B
G3NA-440B(-2)
G3NA-D210B
G3NA-275B-UTU(-2)
G3NA-290B-UTU(-2)
G3NA-475B-UTU(-2)
G3NA-490B-UTU(-2)
2. With constant current input circuit system. The impedance for the G3NA-2@@B-UTU is 15 mA max.
3. Refer to Temperature Characteristics (for Must Operate Voltage and Must Release Voltage) in Engineering Data on page 7 for further
4. The G3NA-240B(-UTU) is 72kΩ±20%.
5. The G3NA-240B(-UTU) is 20 VAC min.
2. When an OMRON Heat Sink (refer to Options) or a heat sink of the specified size is used.
Model
Model
the input impedance is measured at 120 VAC).
details.
on page 6.
5 to 24 VDC
100 to 120 VAC
200 to 240 VAC
5 to 24 VDC
100 to 240 VAC
5 to 24 VDC
100 to 240 VAC
5 to 24 VDC
100 to 240 VAC
24 to 240 VAC 19 to 264 VAC 0.1 to 5 A (at 40°C)
200 to 480 VAC 180 to 528 VAC 0.2 to 10 A (at 40°C) 0.2 to 4 A (at 40°C)
5 to 200 VDC
24 to 240 VAC 19 to 264 VAC 1 to 75 A (at 40°C)
200 to 480 VAC 180 to 528 VAC 1 to 75 A (at 40°C)
Rated voltage
Rated load
voltage
4 to 220 VDC
Load voltage
4 to 32 VDC
75 to 132 VAC
150 to 264 VAC
4 to 32 VDC
75 to 264 VAC
4 to 32 VDC
75 to 264 VAC
4 to 32 VDC
75 to 264 VAC
range
Operating
voltage
0.1 to 10 A (at 40°C) 0.1 to 4 A (at 40°C)
0.1 to 20 A (at 40°C) 0.1 to 4 A (at 40°C)
0.1 to 40 A (at 40°C) 0.1 to 6 A (at 40°C)
0.2 to 20 A (at 40°C) 0.2 to 4 A (at 40°C)
0.2 to 40 A (at 40°C) 0.2 to 6 A (at 40°C)
0.1 to 10 A (at 40°C) 0.1 to 4 A (at 40°C)
1 to 90 A (at 40°C)
1 to 90 A (at 40°C)
With heat sink
(See note 2.)
7 mA max. (See note 2.) 4 VDC max.
36 kΩ±20% (See note 4.) 75 VAC max. (See note 3.) 20 VAC min. (See note 3.)
72 kΩ±20%
5 mA max. (See note 2.) 4 VDC max.
72 kΩ±20%
15 mA max.
72 kΩ±20%
7 mA max.
72 kΩ±20%
Load current (See note 1.)
(See note 1.)
Impedance
0.1 to 3 A (at 40°C)
1 to 7 A (at 40°C)
1 to 7 A (at 40°C)
1 to 7 A (at 40°C)
1 to 7 A (at 40°C)
Without heat sink
4 VDC max.
4 VDC max.
150 VAC max. (See note 3.) 40 VAC min. (See note 3.)
75 VAC max.
75 VAC max.
75 VAC max.
Must operate voltage
60 A (60 Hz, 1 cycle)
150 A (60 Hz, 1 cycle)
220 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
150 A (60 Hz, 1 cycle)
220 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
20 A (10 ms)
800 A (60 Hz, 1 cycle)
1,000 A (60 Hz, 1 cycle)
800 A (60 Hz, 1 cycle)
1,000 A (60 Hz, 1 cycle)
Inrush current
Voltage level
1 VDC min.
1 VDC min.
20 VAC min.
1 VDC min.
20 VAC min.
1 VDC min.
20 VAC min.
Must release voltage
600 V (V
1,200 V (V
400 V (V
600 V (V
1,200 V (V
(reference value)
V
DRM
(See note 5.)
DRM
CEO
DRM
G3NA
, V
DRM
DRM
)
)
)
CEO
)
)
4

Related parts for G3NA-225B-AC100-120