E3S-AR86 Omron, E3S-AR86 Datasheet - Page 24

Industrial Photoelectric Sensors PNP POLAR RETROREFL

E3S-AR86

Manufacturer Part Number
E3S-AR86
Description
Industrial Photoelectric Sensors PNP POLAR RETROREFL
Manufacturer
Omron
Type
Photoelectric Sensorr
Series
E3S-Ar
Datasheets

Specifications of E3S-AR86

Features
Control the laser with digital fiber amplifier
Height
22.3 mm
Length
40 mm
Maximum Operating Temperature
+ 55 C
Minimum Operating Temperature
- 25 C
Operating Supply Voltage
10 V to 30 V
Width
12.4 mm
Sensing Distance
2 m
Output Configuration
PNP
Output Current
100mA
Sensor Output
PNP
Supply Voltage Range Dc
10V To 30V
Sensing Range Max
2m
Sensor Housing
Rectangular
Switch Terminals
Connector
Sensor Input
Optical
Sensing Method
Retroreflective
Sensing Object
Mirror
Sensing Light
Red
Mounting Type
Chassis Mount
Current - Supply
30mA
Voltage - Supply
10 V ~ 30 V
Package / Case
Module, Connector
Sensing Mode
Polarized Retroreflective
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E3S-AR86
Manufacturer:
OMRON
Quantity:
298
Power Supply
When using a commercially available switching regulator, ground the
FG (frame ground) and G (ground) terminals.
If not grounded, switching noise in the power supply may cause
malfunction.
Example of Connection with S3D2 Sensor Controller
DC Three-wire NPN Output Sensors
Reverse operation is possible using the signal input switch on the
S3D2.
http://www.ia.omron.com/
Blue 0 V
Black OUT
Brown +12 V
S3D2
10
7
4
1
11
8
5
2
12
9
6
3
Photoelectric Sensors Technical Guide
● Mounting
Attachment to Moving Parts
To mount the Photoelectric Sensor to a moving part, such as a robot
hand, consider using a Sensors that uses a bending-resistant cable
(robot cable).
Although the bending repetition tolerance of a standard cable is
approximately 13,000 times, robot cable has an excellent bending
tolerance of approximately 500,000 times.
Cable Bending Destruction Test (Tough Wire Breaking
Test)
With current flowing, bending is repeated to check the number of
bends until the current stops.
The testing conditions of the standard cable and robot cable are
different.
Refer to the values in the above table to check bend-resistant
performance under actual working conditions.
Test
Result
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
Bending
angle (θ)
Bending
repetitions
Weight
Operation
per bending
Bending
radius of
support
points (R)
Specimen
Approx. 13,000 times
Left/right 90° each
VR (H) 3 x18/0.12
(1) through (3) in
(1)
Standard cable
figure once
5 mm
300g
R
---
θ
(2)
θ
Weight
conductive electrical wire
Approx. 500,000 times
(3)
2 x 0.15 mm
Robot cable: Strong,
Left/right 45° each
60 bends/minute
(1) through (3) in
figure once
2.5 mm
200g
2
, shielded
C-4