SDP8611-002 Honeywell, SDP8611-002 Datasheet - Page 2

Board Mount Optical Sensors 0.6 mW/cm2 maximum 10kOhm PULL UP 100mW

SDP8611-002

Manufacturer Part Number
SDP8611-002
Description
Board Mount Optical Sensors 0.6 mW/cm2 maximum 10kOhm PULL UP 100mW
Manufacturer
Honeywell
Datasheet

Specifications of SDP8611-002

Operating Supply Voltage
4.5 V to 12 V
Maximum Power Dissipation
100 mW
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Package / Case
Side Looker
Diameter, Lead
0.02 In.
Dimensions
0.225 H × 0.175 W In.
Length, Lead
0.5 In.
Package Type
Side-Looking Plastic
Temperature, Operating, Maximum
85 °C
Temperature, Operating, Minimum
–40 °C
Time, Fall
15 ns
Time, Rise
60 ns
Transistor Polarity
NPN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Infrared Assemblies
Through Beam Modules
ABSOLUTE MAXIMUM RATINGS (25 °C free-air temperature
unless otherwise noted)
Operating Voltage
Operating Temperature
Storage Temperature
ELECTRICAL CHARACTERISTICS (25 °C unless otherwise noted)
Note:
1.
SCHEMATIC
2 Honeywell MICRO SWITCH Sensing and Control
Parameter
Operating Supply Voltage
Low Level Output Voltage
High Level Output Voltage
Output Sink Current
Response Time
Emitter
Detector
Emitter and detector modules are tested to ensure operation at minimum separation of 63,5 mm (2.5 in) when
properly aligned.
2 to 7 V
5 to 12 V
0 °C to 50 °C (32 °F to 122 °F)
-20 °C to 85 °C (-4 °F to 185 °F)
Symbol
V
V
V
t
I
ON
OL
CC
OH
OL
Min
4.5
4.5
10
Typ
5
Max
0.4
12
For application help: call 1-800-537-6945
CAUTION
STRESS DAMAGE
Functional operation of the device at
or above “Absolute Maximum
Ratings” for extended periods of time
may affect reliability.
Failure to comply with these
instructions may result in product
damage.
Unit
mA
V
V
V
HOA6299 Series
s
Light path blocked (Note 1)
Light path not blocked
V
V
V
CC
CC
CC
Test Condition
=5 V, I
=5 V, V
=5 V, I
T
V
(Note 1)
A
CC
=
25 °C
=5 V
OH
OH
OL
=10 mA
=0 mA
=0.4 V

Related parts for SDP8611-002