AT42QT1070-MMH Atmel, AT42QT1070-MMH Datasheet - Page 31

IC TOUCH SENSOR 7KEY 20-VQFN

AT42QT1070-MMH

Manufacturer Part Number
AT42QT1070-MMH
Description
IC TOUCH SENSOR 7KEY 20-VQFN
Manufacturer
Atmel
Type
Capacitiver
Datasheets

Specifications of AT42QT1070-MMH

Number Of Inputs/keys
7 Key (Comms), 5 Key (Standalone)
Data Interface
I²C
Voltage Reference
Internal
Voltage - Supply
1.8 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
20-VFQFN Exposed Pad
Supply Voltage
1.8 V to 5.5 V
Dimensions
3 mm L x 3 mm W x 0.8 mm H
Temperature Range
- 40 C to + 85 C
Termination Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Supply
-
Resolution (bits)
-
Touch Panel Interface
-
Data Rate/sampling Rate (sps, Bps)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT42QT1070-MMH QS529
Manufacturer:
Atmel
Quantity:
9 390
Appendix A.
A.1
A.2
A.3
9596A–AT42–10/10
Interface Bus
Transferring Data Bits
START and STOP Conditions
I
2
C-compatible Operation
The device communicates with the host over an I
an overview of the bus; more detailed information is available from www.i2C-bus.org. Devices
are connected to the I
to Vdd via pull-up resistors. The bus drivers of all I
type. This implements a wired “AND” function that allows any and all devices to drive the bus,
one at a time. A low level on the bus is generated when a device outputs a zero.
Figure A-1.
Each data bit transferred on the bus is accompanied by a pulse on the clock line. The level of the
data line must be stable when the clock line is high; the only exception to this rule is for
generating START and STOP conditions.
Figure A-2.
The host initiates and terminates a data transmission. The transmission is initiated when the
host issues a START condition on the bus, and is terminated when the host issues a STOP
condition. Between the START and STOP conditions, the bus is considered busy. As shown in
Figure
when the SCL line is high.
A-3, START and STOP conditions are signaled by changing the level of the SDA line
SDA
SCL
I
Data Transfer
2
C-compatible Interface Bus
SDA
SCL
Device 1
2
C-compatible bus as shown in
Device 2
Data Stable
Device 3
Data Change
2
C-compatible bus. The following sections give
2
C-compatible devices must be open-drain
Data Stable
Figure
Device n
A-1. Both bus lines are connected
R1
Vdd
AT42QT1070
R2
31

Related parts for AT42QT1070-MMH