1679346 Phoenix Contact, 1679346 Datasheet - Page 2

HEAVYCON INSERT MODULE ML 2POS

1679346

Manufacturer Part Number
1679346
Description
HEAVYCON INSERT MODULE ML 2POS
Manufacturer
Phoenix Contact
Series
HEAVYCON® Mr
Datasheet

Specifications of 1679346

Connector Type
Module
Gender
Male
Number Of Positions
2
Termination Style
Screw
Voltage Rating
600V
Current Rating
40A
Contact Material
Copper Alloy
Contact Plating
Silver
Insert / Contact Gender
Male
Number Of Positions / Contacts
2
Product Type
Inserts
Wire Gauge Range
12-10
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Size
-
Contact Type
-
Lead Free Status / Rohs Status
No
Other names
HC-M-02-MOD-ST
HC-M-02-MOD-ST
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1679346
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
Mechanical characteristics
Conductor cross-section
Connection cross-section AWG
Stripping length of the individual wire
Tightening torque
Wire diameter including insulation
Hexagonal socket
Insertion/withdrawal cycles
General characteristics
Number of module slots
Connection method
Connection in acc. with standard
Inflammability class acc. to UL 94
Pollution degree
Surge voltage category
Assembly instructions
Connection
Order No.: 1679346
2.5 mm² ... 8 mm²
12 ... 10
8 mm + 1 (for 6 mm
5 mm + 1 (For 2.5 mm
11 mm +1 (for 8 mm²)
1.5 Nm (2.5 - 4 mm
2 Nm (6 -8 mm
6 mm (6 mm²)
10.5 mm (8 mm²)
4 mm (2.5 mm² ... 4 mm²)
WAF 2
≥ 500
1
Axial screw connection
IEC / EN
V0
3
III
- Connection of the wires using a 2 mm Allen wrench.- Housing
height ≥ 52 mm.- Axial screw connection only for flexible wires.-
Plug-in connections may only be operated only when there is no
load/voltage.
Note regarding axial connection technology: Only for stranded
wires. The conductor cross-sections stated refer to the geometric
cross-section of the cable used.Use of cables with a geometric
cross-section very different from that of the cable's nominal cross-
section should be checked before use.The wiring space of the
axial screw method is designed for fine strand cables according
to VDE 0295 class 5. Deviating cable structures (e.g. class
6 cables) should be checked before use.Connection Before
starting to connect, ensure that the tapered screw is turned back
all the way (chamber is open). The cables must not be twisted.
The cores should be slid to the limit stop in the contact chamber
(until insulation touches contact). Hold cores in position and use
socket wrench to tighten. The used core end should be cut off
before connecting again. The connection screw may only be
retightened once to prevent the strands from breaking. To prevent
damage to the contact, the core / cable should be mechanically
intercepted at an appropriate distance from the connection
point (e.g. by using a plate cutout). DIN VDE 0100-520:2003-06
contains information on how to do this correctly.
2
)
2
2
)
)
2
... 4 mm
2
)
Jan 27, 2011
Page 2 / 5