RTV11-1P MG Chemicals, RTV11-1P Datasheet - Page 3

no-image

RTV11-1P

Manufacturer Part Number
RTV11-1P
Description
POTTING COMPOUND SILICONE 2 PART
Manufacturer
MG Chemicals
Series
RTVr
Type
Potting Compound, 2 Partr
Datasheets

Specifications of RTV11-1P

Product
Silicones
Size
1 pint
Application
High voltage power supply potting
Chemical Component
Silicone
Color
White
Dielectric Strength
515 V⁄mil
Elongation
160
Hardness
41 (Shore A)
Primary Type
Adhesive
Special Features
Cushions Against Mechanical Shock
Specific Gravity
1.19
Temperature Range
-60 to 204 °C
Temperature, Rating
-60 to +204 °C
Tensile Strength
2.06 Mpa (300 psi)
Thermal Conductivity
0.29 W⁄m.°K
Time, Cure
24 hr
Viscosity
11000 cps @ 25 °C
Volume Resistivity
1 x 10^13 ohm · cm
Weight
1 Pint
For Use With/related Products
Multi-Purpose
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SENSITIVITY TO MECHANICAL IMPACT:
SENSITIVITY TO STATIC DISCHARGE
EXTINGUISHING MEDIA
SPECIAL FIRE FIGHTING PROCEDURES
6. ACCIDENTAL RELEASE MEASURES
ACTION TO BE TAKEN IF MATERIAL IS RELEASED OR SPILLED
7. HANDLING AND STORAGE
PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
STORAGE
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
ENGINEERING CONTROLS
RESPIRATORY PROTECTION
PROTECTIVE GLOVES
RTV11 001-KIT (1.0 Lbs-0.454 Kg)
SILICONE RUBBER COMPOUND
Sensitivity to static discharge is not expected.
All standard extinguishing agents are suitable.
Firefighters must wear NIOSH/MSHA approved positive pressure self-contained breathing
apparatus with full face mask and full protective clothing.
Wipe, scrape or soak up in an inert material and put in a container for disposal. Wash walking
surfaces with detergent and water to reduce slipping hazard. Wear proper protective equipment as
specified in the protective equipment section.
Avoid inhalation of vapour or mist. Avoid contact with skin and eyes. Use only in well-ventilated areas.
Keep container tightly closed. Keep out of the reach of children.
Eyewash stations; Use only in well-ventilated areas.
If exposure limits are exceeded or respiratory irritation is experienced, NIOSH/MSHA approved
respiratory protection should be worn. Supplied air respirators may be required for non-routine or
emergency situations. Respiratory protection must be provided in accordance with OSHA regulations
(see 29CFR 1910.134).
Impermeable or chemical resistant gloves.
Page 3/7
No
Material Safety Data Sheet
Version: 1.4
06/16/2008