KSC541J C&K Components, KSC541J Datasheet - Page 8

SWITCH TACT 300GF J-TYPE

KSC541J

Manufacturer Part Number
KSC541J
Description
SWITCH TACT 300GF J-TYPE
Manufacturer
C&K Components
Series
KSC5r
Datasheets

Specifications of KSC541J

Circuit
SPST-NO
Switch Function
Off-Mom
Contact Rating @ Voltage
0.05A @ 32VDC
Actuator Type
Standard
Mounting Type
Surface Mount
Orientation
Vertical
Outline
6.20mm x 6.20mm
Illumination
Non-Illuminated
Operating Force
300gf
Contact Rating
50 mAmps at 32 Volts
Contact Form
SPST
Termination Style
SMD/SMT
Body Size
5.2 mm H
Features
Range of 6 actuation forces
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
401-1084-2
Y31C41664FP
As a conclusion, the new antiparticle contact can reduce significantly any failure linked to particle
inside the switch. This improvement is a major step to go toward zero defects on the KSC series.
3. Change impact and qualification method
The design constrain for this new central contact on the lead frame and the new housing was to get no
modification on any specification to avoid any change on customer application. All product
features, mechanical, electrical, environmental remains unchanged.
The manufacturing & quality processes, location and procedures remain also unchanged.
The qualification proceeds as follows as both modification are dissociated.
You will find in annex 2 the justification of the characteristics choice for the qualification.
You will find in annex 3 a synthesis with all the part numbers test for the antiparticle contact and the
corresponding report for each of them. The full qualification report for the new housing is also included
in annex 4.
C&K
C&K components SAS - 1 rue Louis de la Verne B.P. 359 F-39105 Dole Cedex - FRANCE
Telephone :+33 (0)3 84 72 94 03 - Facsimile: +33 (0)3 84 79 20 39 – www.ck-components.com
Document subject to change without prior notice
Diffusion: no restriction
PCN07-09-KSC Rev.A – 14/11/07
Antiparticle contact qualification on the most common KSC P/N’s. We have qualified the
characteristics for which this new contact may have an impact which are:
New mold housing: A full qualification was done on one P/N. On the main KSC P/N’s, the following
test are the following:
components
o
o
o
o
o
o
o
o
o
o
Forces
Stroke
Contact resistance
Simultaneity
Life test
Forces
Stroke
Contact resistance
Simultaneity
Life test
Observed Performance
LSL
Target
USL
Sample Mean
Sample N
StDev(W ithin) 11.6612
StDev(Overall) 12.5111
PPM < LSL
PPM > USL 0,00
PPM Total
Process Data
0,00
*
*
100
19.675
40
Fig. 9 Mix test results for standard contact
*
Process Capability of Lot 3 Anti particules
Exp. W ithin Performance
PPM < LSL
PPM > USL 0,00
PPM Total
0
16
0,00
*
32
Exp. Overall Performance
PPM < LSL
PPM > USL 0,00
PPM Total
48
64
0,00
*
80
96
USL
Potential (Within) Capability
Overall Capability
W ithin
Overall
Cp
CPL
CPU
Cpk
CCpk
Pp
PPL
PPU
Ppk
Cpm
2,30
2,30
2,30
2,14
2,14
Product change notification
*
*
*
*
*
Page 8/35

Related parts for KSC541J