Specifications of D4DS-1AFS

Circuit
DPST-NC
Switch Function
On-Off
Contact Rating @ Voltage
10A @ 250VAC
Actuator Type
Panel Disconnect
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Operating Force
1471gf
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
D4DS-1AFS
Q2673363
Z2767
D4DS
Specifications
J APPROVED STANDARD RATINGS
TÜV (EN60947-5-1)
Note: Use a 10-A fuse type gl or gG as a short-circuit protection device that conforms to IEC269.
UL (UL508/CSA C22.2 No.14)
A600
J CHARACTERISTICS
Note: 1. Although the Switch casing resists dust, oil, and water, make sure that the keyhole on the head is free from dust, oil, water, and
Utilization category
Rated operating current (I
Rated operating voltage (U
Rated voltage
120 VAC
240 VAC
480 VAC
600 VAC
Degree of protection (see note 1)
Life expectancy (see note 2)
Operating speed
Contact gap
Operating frequency
Positive opening force (see note 3)
Positive opening travel (see note 3)
Insulation resistance
Contact resistance
Dielectric strength
Rated insulation voltage (U
Conditional short-circuit current
Short-circuit protective device (SCPD)
Switching overvoltage
Pollution degree (operating environment)
Conventional enclosed thermal current
(I
Protection against electric shock
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Weight
the
)
2. Life expectancy values are calculated at an operating temperature of 5°C to 35°C, and an operating humidity of 40% to 70%.
3. These figures are minimum requirements for safe operation.
chemical, or the D4DS may wear out, break, or malfunction.
Contact your OMRON sales representative for more detailed information on other operating environments.
Carry current
10 A
e
)
e
i
y
)
)
IP65 (EN60947-5-1)
Mechanical: 1,000,000 operations min.
Electrical: 150,000 operations min.
0.1 m/s to 0.5 m/s
2 x 2.0 mm min.
30 operations/minute min.
58.84 N min.
10 mm min.
100 MΩ min. (at 500 VDC) between terminals of same polarity, between terminals of
different polarity, between each terminal and ground, and between each terminal and
non-current-carrying metal part
25 mΩ max. (initial value)
U
between each terminal and non-current-carrying metal part (EN60947-5-1)
400 V (EN60947-5-1)
100 A (EN60947-5-1)
10 A, fuse type gI or gG (IEC269)
1,500 V max. (EN60947-5-1)
3 (EN60947-5-1)
10 A (EN60947-5-1)
Class II (double insulation)
Malfunction: 10 to 500 Hz, 0.65-mm single amplitude with an imposed acceleration of
100 m/s
Destruction: 1,000 m/s
Malfunction: 300 m/s
Operating: --30°C to 70°C (with no icing)
Operating: 95% max.
Approx. 76 g (for D4DS-15FS)
AC-15
2 A
400 V
Current
Make
60 A
30 A
15 A
12 A
imp
4 kV between terminals of same polarity, between terminals of different polarity, and
2
max.
2
min.
2
4
Break
6 A
3 A
1.5 A
1.2 A
min.
Volt-amperes
Make
7,200 VA
Break
720 VA