Specifications of SHL-Q2155-L4MR VCTF 3M

Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
10A @ 125VAC
Actuator Type
Roller Plunger
Mounting Type
Panel Mount
Termination Style
Cable Leads
Operating Force
981gf
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
SHL-Q2155-L4MRVCTF3M
SHLQ2155L4MRVCTF3M
Ratings
Note: 1. The above figures are for steady-state currents.
Micro load models
Characteristics
Structure and Nomenclature
Structure
Degree of protections
Durability
Operating speed
Operating
frequency
Rated frequency
Insulation resistance
Contact resistance
Dielectric strength
Rated insulation voltage (Ui)
Pollution degree (operating environment)
Short-circuit protective device (SCPD)
Conditional short-circuit current
Conventional enclosed thermal current (I
Protection against electric shock
OFF reverse voltage
Vibration resistance Malfunction
Shock
resistance
Ambient operating temperature
Ambient operating humidity
Weight
125 VAC
250 VAC
480 VAC
125 VDC
250 VDC
125 VAC
voltage
current
voltage
Inrush
Rated
Rated
14 VDC
30 VDC
14 VDC
30 VDC
8 VDC
8 VDC
Terminal protection cover
2. Inductive loads have a power factor of 0.4 min. (AC) and a time
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
constant of 7 ms max. (DC).
Non-inductive load (A)
NC
Resistive
NC
NO
Non-inductive load (A)
NC
Resistive load
load
10
10
10
10
0.4
0.2
2
5
NO
0.1
0.1
0.1
0.1
Mechanical
Electrical
Mechanical
Electrical
Between terminals of the
same polarity
Between each terminal and
non-current-carrying metal
part
Destruction
Malfunction
15 A max.
15 A max.
(For SHL-W155)
Screw terminal
NO
NC
Lamp load
1.5
1.5
1.5
0.4
0.2
2
2
Movable plunger
Rubber cap (NBR)
the
NO
)
Seal packing (NBR)
NC
Inductive
Die-cast case
(zinc die-cast)
load
0.05
0.03
IP67 (EN60947-5-1)
10,000,000 operations min.
500,000 operations min.
0.1 mm/s to 0.5 m/s (hinge lever models)
120 operations/min
30 operations/min
50/60 Hz
100 MΩ min. (at 500 VDC)
15 mΩ max. (initial value for the built-in switch when
tested alone)
1,000 VAC, 50/60 Hz for 1 min
2,000 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV
(EN60947-5-1)
150 V (EN60947-5-1)
3 (EN60947-5-1)
10 A fuse type gI or gG (IEC60269)
100 A (EN60947-5-1)
5 A (EN60947-5-1)
Class II (grounding not required with double insulation)
1,000 VAC max., 300 VDC max. (EN60947-5-1)
10 to 55 Hz, 1.5-mm double amplitude
1,000 m/s
300 m/s
−10°C to +80°C (with no icing)
35% to 95%RH
Approx. 62 to 72 g
1.5
Inductive load (A)
Seal rubber (NBR)
3
2
5
5
NO
2
min.
2
min.
Motor load
NC
0.05
0.03
2.5
1.5
1.5
2
2
NO
Approved Standard Ratings
TÜV (EN60947-5-1), CCC (GB14048.5)
Note: "AC-15 2 A/125 V" indicates the following.
UL/CSA
A300
Contact Form
SHL-@55
SHL-@55-01
SHL-@55-L
SHL-@55-01L
SHL-@55-01L2
SHL-@55-L3
SHL-@55-01L3
SHL-@55-L4
SHL-@55-01L4
SHL-@55-L5
SHL-@55-01L5
120 VAC
240 VAC
voltage
Rated
Application category: AC-16
Rated operating current (Ie): 2 A
Rated operating voltage (Ue): 125 V
Model
current
Carry
10 A
Note: 1. The figures at the left are initial values.
*1. The head section of the plunger type SHL-D(Q)@@ is
*2. Durability values are calculated at an operating
*3. The values are for the plunger-type models.
(COM) 1
excluded.
temperature of +5°C to +35°C, and an operating
humidity of 40% to 70%RH.
2. The ratings at the left may vary depending on
1,000
Engineering Data
Electrical Durability
(Ambient temperature: +5°C to +35°C,
Ambient humidity: 40% to 50%RH)
700
500
300
100
70
50
30
10
the model. Contact your OMRON
representative for further details.
7
5
3
1
Category and rating
0
Make
AC-15
DC-12
AC-14
DC-12
AC-15 2 A/125 V
AC-14 0.1 A/125 V
DC-12 0.1 A/12 V
DC-12 2 A/24 V
DC-12 0.1 A/24 V
DC-12 2 A/24 V
DC-12 0.1 A/24 V
DC-12 2 A/48 V
DC-12 0.1 A/48 V
60
30
Current (A)
1
2
2 A/125 V
2 A/48 V
0.1 A/125 V
0.1 A/48 V
Break
3
6
3
4
2 (NC)
4 (NO)
250 VAC
5
Make
7,200
Volt-amperes (V)
Operating frequency:
30 operations/min.
(cos dia. = 1)
6
Switching current (A)
7
0.5 A
0.5 A
0.5 A
0.5 A
0.5 A
0.5 A
0.5 A
I the
5 A
5 A
5 A
5 A
5 A
5 A
8
SHL
Break
720
9
10
3