HL-5030G Omron, HL-5030G Datasheet
HL-5030G
Specifications of HL-5030G
Related parts for HL-5030G
HL-5030G Summary of contents
Page 1
... HL-5000 HL-5030 Note: HL-5000 Limit Switches are offered with a choice of ground terminal/M5 tapping on the rear side conforming to various standards. When placing an order, add the code to the model number to indicate if ground terminal/M5 tapping on the rear side is required. -G: with ground terminal/M5 tapping on the rear side. ...
Page 2
... Non-inductive load Lamp load 1 0.2 A --- 0.2 A --- 24 A max max. HL-5000 Head (individual) Lever (individual) HL-1HPH01 (HL5 0028A) HL-1HPA100 (HL5 0025G) HL-1HPH01 (HL5 0028A) HL-1HPA300 (HL5 0026E) HL-1HPH01 (HL5 0028A) HL-1HPA500 (HL5 0027C) --- --- --- --- --- --- --- --- Inductive load Inductive load Motor load ...
Page 3
... The values are calculated at an operating temperature and an operating humidity of 40% to 70%. Contact your OMRON sales representative for more detailed information on other operating environments. 4. These values do not apply to the coil spring model. See the following Electrical Durability. 30 operations/min 2 min. 2 min. (see note 4) General-purpose Limit Switch HL-5000 K-7 ...
Page 4
... Contact Form (NO (NC) 1 Nomenclature Resin roller Lever Head Cover Built-in switch Connector Engineering Data Electrical Durability (cos =1) Operating temperature: 5°C to 35°C Operating humidity: 40% to 70% Operating frequency: 30 operations/min 125 VAC (cosφ Switching current (A) K-8 General-purpose Limit Switch 3 (NO) 2 (NC) HL-5000 ...
Page 5
... Note: The head can be mounted in any of the four directions. Dimensions not shown are the same Sealed Plunger as HL-5000. HL-5100 PT 8 dia. OP ± 50 0.2 4.1 Note: Dimensions not shown are the same as HL-5000. 31.5R (See note 2) Three × 12 cover Allen-head clamping bolt screws Rubber connector 17.5 dia. × ...
Page 6
... Note: 1. The coil spring may be operated from any direc- 2. The operating range of the dog or cam is the top 3. Dimensions not shown are the same as Note: OF and RF measured at the arm length for HL-5030, and 145 mm for HL-5050 (reference values). Model HL-5030 OF 3 ...
Page 7
... Head mounting screw can be turned with either (Black non-removable a Phillips head or torque screw) flat-blade screwdriver) HL-5050 The head of the HL-5200 can be mounted in two directions only. Refer to the following illustration. HL-5200 Head mounting screw (white) Head mounting screw (white) HL-5000 ...
Page 8
... Two, M5 screws or 5.2-dia. holes (located diagonally for securing the front side) Only the HL-5@@@G has M5 x 0.8 screw holes on the rear side. Others Do not use the Limit Switch outdoors, otherwise the Limit Switch will become damaged by rust or ozone. ...
Page 9
... Switch mounting screw 4.90 to 5.88 N·m (M5 Allen-head bolt) Note: If the head direction has been changed, check the torque of each screw and make sure that the screws are free of foreign substances, and that each screw is tightened to the proper torque General-purpose Limit Switch HL-5000 K-13 ...
Page 10
... ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. C004-E2-11 In the interest of product improvement, specifications are subject to change without notice. K-14 General-purpose Limit Switch HL-5000 ...