D4E-1A10N Omron, D4E-1A10N Datasheet - Page 4

SWITCH SPDT 5A 125V ROLLER PLNGR

D4E-1A10N

Manufacturer Part Number
D4E-1A10N
Description
SWITCH SPDT 5A 125V ROLLER PLNGR
Manufacturer
Omron
Series
D4E-xNr
Type
Miniature Enclosed Limit Switchr
Datasheet

Specifications of D4E-1A10N

Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
1A @ 125VAC
Actuator Type
Roller Plunger
Mounting Type
Chassis Mount
Termination Style
Connector
Operating Force
1177gf
Actuator Style
Roller Lever
Operating Force Max
11.77N
Contact Voltage Ac Max
125V
Contact Voltage Dc Max
30V
Contact Current Ac Max
5A
Contact Current Dc Max
1A
Switch Terminals
Connector
Contact Rating
5 Amps at 125 Volts, 250 Volts
Actuator
Roller Plunger
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
D4E1A10N
Note: 1. The above current ratings are for a standard current and the values in parentheses are for models with a connector.
Note: 1. The above values are initial values.
125 VAC
250 VAC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
Inrush current
Degree of protection
Durability (see note 3)
Operating speed
Operating frequency
Rated frequency
Insulation resistance
Contact resistance
Dielectric strength
Rated insulation voltage (Ui)
Switching overvoltage
Pollution degree (operating environment)
Short-circuit protective device (SCPD)
Conditional short-circuit current
Conventional enclosed thermal current (I
Protection against electric shock
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Weight
Rated voltage
General Ratings
Characteristics
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
2. The above ratings may vary depending on the model. Contact your OMRON representative for further details.
3. Durability values are calculated at an operating temperature of 5 C to 35 C, and an operating humidity of 40% to 70%. Contact your
OMRON sales representative for more detailed information on other operating environments.
5 (1) A
5 (1) A
5 (1) A
5 (1) A
5 (1) A
0.5 A
0.25 A
NC
NO
NC
Resistive load
Non-inductive load
NO
the
1.5 (1) A
1.5 (1) A
---
---
---
---
---
10 A max.
10 A max.
) 5 A (EN60947-5-1)
NC
IP67
Mechanical: 10,000,000 operations min.
Electrical:
0.1 mm to 0.5 m/sec
Mechanical: 120 operations/min
Electrical:
50/60 Hz
100 M
15 m
1,000 VAC, 50/60 Hz for 1 min between terminals of same polarity
1,500 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1) between current-carrying metal
parts and ground, and between each terminal and non-current-carrying metal part
250 VAC
1,000 VAC max. (EN60947-5-1)
3 (EN60947-5-1)
10 A fuse (type gG or gI, IEC269 approved)
100 A (EN60947-5-1)
Class II (grounding not required with double insulation)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction: 1,000 m/s
Malfunction: 300 m/s
Operating: –10 C to 80 C (with no icing)
Operating: 35% to 95%
Approx. 86 g (in case of roller plunger)
Lamp load
max. (initial value)
min. (at 500 VDC)
NO
Standard load
500,000 operations min. (5 A at 250 VAC, resistive load)
5,000,000 operations min. (10 mA at 24 VDC, resistive load)
30 operations/min
3 (1) A
3 (1) A
1.5 (1) A
1.5 (1) A
1.5 (1) A
0.05 A
0.03 A
2
min.
2
min.
NC
Inductive load
NO
Inductive load
Small Sealed Switch
2 (1) A
1 A
---
---
---
---
---
NC
Motor load
1 (1) A
0.5 A
NO
D4E-@N
0.1 A
---
0.1 A
0.1 A
0.1 A
---
---
Non-inductive load
NC
Resistive load
Micro load
NO
141

Related parts for D4E-1A10N