... High contact reliability ensured with gold crossbar contacts. RoHS Compliant Ordering Information Model Number Legend ■ D3D-@@ Actuator 1: Plunger 2: Lever 2. Contact Form 1: SPDT 2: SPST-NC 3: SPST-NO List of Models ■ Actuator Contact form SPDT Plunger D3D-111 Lever D3D-211 SPST-NC SPST-NO D3D-121 D3D-131 D3D-221 D3D-231 D3D 1 ...
... Electrical: 50,000 operations min. (20 operations/min) Degree of protection IEC IP00 Degree of protection against elec- D3D-1 models (plunger models): Class II tric shock D3D-2 models (lever models): Proof tracking index (PTI) 600 −30°C to 60°C (at ambient humidity of 60% max.) (with no icing or condensation) ...
... Note: The dimensions OP1 and OP2 apply to the D3D-211 only. The D3D-221 and D3D-231 are SPST-NC and SPST-NO respectively and so therefore have only one corresponding dimension here (OP). Mounting Panel Cutout Dimensions ■ Note All units are in millimeters unless otherwise indicated. 0 22.9 − ...
... Even when using the Switch within the operating range, if there are inrush currents or surges, it may decrease the durability of the Switch. If necessary, insert a contact protection circuit. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. B107-E1-02 4 D3D ...