D2D-1100 Omron, D2D-1100 Datasheet - Page 2

SWITCH SPDT(DB) 16A DOOR INTRLOC

D2D-1100

Manufacturer Part Number
D2D-1100
Description
SWITCH SPDT(DB) 16A DOOR INTRLOC
Manufacturer
Omron
Series
D2Dr
Type
Door Interlock Switchr
Datasheets

Specifications of D2D-1100

Actuator Type
Round (Pin Plunger)
Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
16A @ 125VAC
Mounting Type
Panel Mount, Snap-In
Termination Style
Quick Connect - .250" (6.3mm)
Operating Force
600gf
Contact Form
SPDB - NO / NC
Contact Rating
16 Amps
Actuator
Plunger
Contact Configuration
SPDT-1NO / 1NC
Contact Voltage Ac Max
250V
Contact Current Ac Max
16A
Switch Terminals
Quick Connect
Svhc
No SVHC (15-Dec-2010)
Approval Bodies
UL, VDE, CSA,
Pole Throw Configuration
SP
Switch Function Configuration
N.O./N.C.
Current Rating (max)
16A
Operating Temp Range
-25C to 85C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
D2D-1100
D2D1100
SW982
D2D
Specifications
Note:
Note:
2
Standard
Pull-on lock
Operating speed
Operating frequency
Insulation resistance
Contact resistance
(initial value)
Dielectric
strength (50/
60 Hz 1mm)
Vibration resistance
Shock resistance
Durability (see note 3)
Degree of protection
Degree of protection against electric
shock
Proof tracking index (PTI)
Ambient operating temperature
Ambient operating humidity
Weight
Ratings
Characteristics
Type
The ratings values apply under the following test conditions:
Ambient temperature: 20±2°C
Ambient humidity: 65±5%
Operating frequency: 30 operations/min
1. The data given above are initial values.
2. The dielectric strength shown in the table indicates a value for models with a Separator.
3. For testing conditions, consult your OMRON sales representative.
Between terminals of
same polarity
Between terminals and
ground (see note 2)
Between terminals and
non-current-carrying
metal part
Between terminals and
actuator
Item
250 VAC
250 VAC
Rated voltage
Item
16 A
10 A
Resistive load
10 mm to 1 m/s
Mechanical: 300 operations/min max.
Electrical:
100 MΩ min. (at 500 VDC)
50 mΩ max.
2,000 VAC
2,000 VAC
2,500 VAC
4,000 VAC
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction: 1,000 m/s
Malfunction:500 m/s
{approx. 50G} max.
Mechanical: 10,000,000 operations min. (60 operations/min)
Electrical:
IEC IP40
Class II
175
–25°C to 85°C (at ambient humidity of 60% max.) (with no icing or condensation)
85% max. (for 5°C to 35°C)
Approx. 14 g (D2D-1000)
D2D-1000 models
30 operations/min max.
100,000 operations min. (30 operations/min)
2
2
{approx. 100G} max.
1,000 VAC
1,500 VAC
1,500 VAC
---
Malfunction:300 m/s
{approx. 30G} max.
D2D-2000 models
2
2,000 VAC
2,000 VAC
---
4,000 VAC
Malfunction:500 m/s
{approx. 50G} max.
D2D-3000 models
2
D2D

Related parts for D2D-1100