ZE-NJ-2S Omron, ZE-NJ-2S Datasheet - Page 2

SWITCH LIMIT SPRING SPDT 15A

ZE-NJ-2S

Manufacturer Part Number
ZE-NJ-2S
Description
SWITCH LIMIT SPRING SPDT 15A
Manufacturer
Omron
Series
ZEr
Type
Enclosed Limit Switchr
Datasheets

Specifications of ZE-NJ-2S

Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
15A @ 125VAC
Actuator Type
Coil Spring
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Operating Force
150gf
Contact Form
SPDT
Contact Rating
15 Amps at 125 Volts
Actuator
Rod, Flexible
Actuator Style
Wobble Coil Spring Lever
Operating Force Max
1.47N
Contact Voltage Ac Max
480V
Contact Voltage Dc Max
250V
Contact Current Ac Max
15A
Contact Current Dc Max
500mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
Z1059
ZENJ2S
Ordering Information
Note: 1. The diagonal side mounting model feature improved sealing property, improved mounting strength through use of M5 screws, increased stability in seating with
Specifications
Approved Standards
Note: 1. Models XE, XV, and XV2 are not approved by UL, CSA, and CCC.
Ratings
Actuator
General
purpose
Sealed
(Booted)
UL
CSA
CCC (CQC)
ZE-@
ZV-@
ZV2-@
XE-@
XV-@
XV2-@
Model
2. Ask your OMRON representative for information on models with ground terminals.
2. Ask your OMRON representative for information on approved models.
Agency
large mounting width (31 x 75 mm) and permit coupling of a number of Switch units.
Plunger
Roller plunger
Crossroller plunger
Roller arm lever
One-way action roller
arm lever
Sealed plunger
Sealed roller plunger
Sealed crossroller
plunger
Sealed roller arm lever
One-way action
sealed roller arm lever
125 VAC
250 VAC
480 VAC
125 VDC
250 VDC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
voltage
Rated
Resistive load
NC
CSA C22.2 No.14
GB14048.5
Standard
Non-inductive load (A)
0.5
0.25
10
10
10
10
15
15
10
3
UL508
NO
Mounting
3
2.5
1.5
3
3
3
3
1.5
NC
Lamp load
AC
DC
AC
DC
AC
DC
AC
DC
AC
DC
AC
DC
AC
AC
AC
DC
AC
DC
0.5
0.25
2003010303077623
1.5
1.25
0.75
1.5
1.5
1.5
1.5
0.75
NO
ZE-Q-2
XE-Q-2
ZE-Q22-2
XE-Q22-2
ZE-Q21-2
XE-Q21-2
ZE-QA2-2
XE-QA2-2
ZE-QA277-2
XE-QA277-2
ZE-N-2
XE-N-2
ZE-N22-2
ZE-N21-2
ZE-NA2-2
XE-NA2-2
ZE-NA277-2
XE-NA277-2
LR45746
File No.
E76675
Model
Side mounting
Inductive load
NC
10
10
10
7.5
2
0.05
0.03
15
15
6
Inductive load (A)
standards
UL
NO
Approved
10
10
10
6
1.5
CSA
NC
5
3
1.5
Motor load
5
5
5
2
2
0.05
0.03
ZV-Q-2
XV-Q-2
ZV-Q22-2
XV-Q22-2
ZV-Q21-2
XV-Q21-2
ZV-QA2-2
XV-QA2-2
ZV-N-2
XV-N-2
ZV-N22-2
ZV-N21-2
ZV-NA2-2
XV-NA2-2
ZV-NA277-2
2.5
1.5
0.75
Model
NO
2.5
2.5
2.5
2.5
1.5
---
---
---
Base mounting
Note: 1. The above figures are for standard currents.
ZE/ZV/ZV2/XE/XV/XV2
standards
UL
Approved
Inrush
current
2. Inductive loads have a power factor of 0.4 min.
3. Lamp load has an inrush current of 10 times
4. Motor load has an inrush current of 6 times the
(AC) and a time constant of 7 ms max. (DC).
the steadystate current.
steady-state current.
CSA
NC
NO
ZV2-Q-2
XV2-Q-2
ZV2-Q22-2
XV2-Q22-2
ZV2-Q21-2
ZV2-QA2-2
XV2-QA2-2
ZV2-QA277-2
ZV2-N-2
XV2-N-2
ZV2-N22-2
ZV2-N21-2
ZV2-NA2-2
XV2-NA2-2
ZV2-NA277-2
XV2-NA277-2
Diagonal side mounting
Model
---
---
30 A max.
15 A max.
standards
UL
Approved
CSA
2

Related parts for ZE-NJ-2S