MRF206 NKK Switches, MRF206 Datasheet - Page 2

SW ROTARY DP 2-6POS PC

MRF206

Manufacturer Part Number
MRF206
Description
SW ROTARY DP 2-6POS PC
Manufacturer
NKK Switches
Series
MRr
Type
Rotaryr
Datasheets

Specifications of MRF206

Number Of Positions
2 ~ 6
Number Of Decks
1
Number Of Poles Per Deck
2
Circuit Per Deck
DP6T
Contact Rating @ Voltage
0.4VA @ 28VAC/DC
Actuator Type
Flush (Slotted)
Mounting Type
PCB, Through Hole
Termination Style
PC Pin
Orientation
Vertical
Angle Of Throw
30°
Body Style
Miniature
Current, Rating
0.1 A
Dielectric Strength
500 VAC
Mounting Hole Size
0.25 "
Number Of Poles
2
Termination
Solder
Voltage, Rating
28 VAC/VDC
No. Of Poles
2
No. Of Switch Positions
6
Contact Current Ac Max
100mA
Contact Current Dc Max
100mA
Contact Voltage Ac Max
28V
Contact Voltage Dc Max
28V
Svhc
No SVHC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
360-2371
MRF206-RO
MRF206-RO
General Specifications
Electrical Capacity (Resistive Load)
Other Ratings
Materials & Finishes
Environmental Data
Installation
Processing
Standards & Certifications
NKK Switches
Common Contacts & Terminals:
Operating Temperature Range:
Soldering Time & Temperature:
Range of Operating Torque:
End Contacts & Terminals:
Cap Installation Force:
Insulation Resistance:
or CSA Certification:
Contact Resistance:
Dielectric Strength:
Movable Contacts:
Bushing/Housing:
Mounting Torque:
For MRF or MRK:
Mechanical Life:
Contact Timing:
UL Recognition
Stopper Plate:
Electrical Life:
Vibration:
Humidity:
Indexing:
Cleaning:
For MRA:
Shock:
Shaft:
Base:
Half-Inch Diameter Process Sealed Rotaries
250mA @ 125V AC
0.4VA maximum @ 28V AC/DC maximum
(Applicable Range 0.1mA ~ 0.1A @ 20mV ~ 28V)
Note: Find additional explanation of operating range in Supplement section.
10 milliohms maximum for MRA; 50 milliohms maximum for MRF & MRK
100 megohms minimum @ 500V DC
1,000V AC minimum for 1 minute minimum for MRA
500V AC minimum for 1 minute minimum for MRF & MRK
30,000 operations minimum
10,000 operations minimum
0.02 ~ 0.07Nm for MRA; 0.005 ~ 0.02Nm for MRF & MRK
Nonshorting (break-before-make)
MRA – self-cleaning, sliding contact; MRF & MRK – self-cleaning, rotary contactor disk
30°
Brass with nickel plating
Steel with zinc plating for MRA & MRK; polyamide cover with stopper for MRF
Zinc alloy with zinc plating
Copper with silver plating for MRA; phosphor bronze with gold plating for MRF & MRK
Brass with silver plating for MRA; phosphor bronze with gold plating for MRF & MRK
Brass with silver plating for MRA; phosphor bronze with gold plating for MRF & MRK
Diallyl phthalate for MRA; fiberglass reinforced polyamide for MRF & MRK
–10°C through +70°C (+14°F through +158°F)
90 ~ 95% humidity for 96 hours @ 40°C (104°F)
10 ~ 55Hz with peak-to-peak amplitude of 1.5mm traversing the frequency range
& returning in 1 minute; 3 right angled directions for 2 hours
50G (490m/s
.686Nm (6.08 lb
19.6 ~ 29.4N (4.41 ~ 6.61 lbf) for MRA & MRK
Wave Soldering for MRA: See Profile A in Supplement section.
Wave Soldering for MRF & MRK: See Profile B in Supplement section.
Manual Soldering for MRA: See Profile A in Supplement section.
Manual Soldering for MRF & MRK: See Profile B in Supplement section.
Automated cleaning recommended. Stopper plate, as well as washers for MRA & MRK, must be in
place to maintain automated cleaning. See Cleaning specifications in Supplement section.
MRA, MRF, & MRK models have not been tested for UL recognition or CSA certification.
These switches are designed for use in a low-voltage, low-current, logic-level circuit.
When used as intended in a logic-level circuit, the results do not produce hazardous energy.
2
) acceleration (tested in 3 right angled directions, with 3 shocks in each direction)
in)
Series MR

Related parts for MRF206