A103J61ZQ00 Tyco Electronics, A103J61ZQ00 Datasheet - Page 19

SWITCH ROCKER SPDT 5A WIRE LUG

A103J61ZQ00

Manufacturer Part Number
A103J61ZQ00
Description
SWITCH ROCKER SPDT 5A WIRE LUG
Manufacturer
Tyco Electronics
Series
Ar
Datasheet

Specifications of A103J61ZQ00

Rohs Information
A103J61ZQ00
Circuit
SPDT
Switch Function
On-Off-On
Contact Rating @ Voltage
5A @ 125VAC
Illumination
Non-Illuminated
Mounting Type
Panel Mount, Snap-In
Termination Style
Solder Lug
Panel Cutout Dimensions
15.24mm x 12.70mm
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Illumination Type, Color
-
Illumination Voltage (nominal)
-
Other names
4-1437591-3
450-1037
Functions available in DP only: Connect terminals:
Wiring Diagrams
for Functions
Rocker
Paddle
Need more technical information?
Consult your Thomas & Betts
sales office listed on the back cover
J1
11
J2
Pos.3
Pos.2
Pos.1
01
03
05
07
08
11
13
15
13
2 Positions
3 Positions
3 Positions
3 Positions
2 Positions
3 Positions
3 Positions
3 Positions
15
"AE" Series Washable Rockers/Paddles
None indicates no mechanical position
Off indicates a mechanical position with no electrical connection.
(On) indicates momentary action.
SPDT, connect terminals:
DPDT, connect terminals:
SP3T Available in DP Format Only
Use beveled frame B200 for enhancement (Pg. E12)
when ordering with terminations other than C or Z.
Use beveled frame B100 for enhancement (Pg. E12)
when ordering with terminations other than C or Z.
SP3T function achieved with
OUT 1
OUT 2
SINGLE POLE 3 POSITION
Unless otherwide specified by terminal type,
Unless otherwide specified by terminal type,
the panel mounting bracket will be supplied.
*
(7.87)
the panel mounting bracket will be supplied.
(8.43)R
.310
(3.96)
.156
.332
Installed by Customer
external jumpers.
6
5
4
(13.49)
(16.87)
.531
.664
(2.13)
3
2
1
.084
(18.8)
(7.59)
.740
JUMPER
IN
OUT 3
.299
*
(9.27)
(9.27)
.365
.365
E19
6 (OUT)
POS. 1
Unless otherwide specified by terminal type,
Use beveled frame B100 for enhancement (Pg. E12)
when ordering with terminations other than C or Z.
the panel mounting bracket will be supplied.
Use beveled frame B200 for enhancement (Pg. E12)
when ordering with terminations other than C or Z.
Unless otherwide specified by terminal type,
the panel mounting bracket will be supplied.
(7.77)
4
.306
(5.84)R
.230
(3.18)
(2.36)
5
.125
.093
(11.68)
1
3
(9.19)
.460
.362
2 (IN)
The Gemini Series
(7.11)
.280
(16.36)
.644
(11.43)
(10.97)
(11.43)
.450
.432
.450
(On)
(On)
1—2
1—2
4—5
(On)
(On)
1—2
4—5
(On)
POS. 2
ALCO
On
On
On
6
4 (OUT)
The following functions available in SP or DP.
5
3
1
(901) 252-5000 FAX (901) 252-1380
None
None
2—3
4—5
2 (IN)
Off
Off
Off
ALCO
On
On
On
2—3
2—3
5—6
2—3
5—6
(On)
(On)
On
On
On
On
On
On
ALCO
Memphis, TN 38125
ACTUATORS
6
FUNCTIONS
POS. 3
4
8155 T&B Blvd.
Thomas & Betts
5
3
1 (OUT)
Rocker
2 (IN)
Paddle
J50