... REED SWITCH ORD9215 General Purpose Miniature n GENERAL DESCRIPTION The ORD9215 is a small single-contact reed switch designed for general control of medium- level loads less than 100 V. The contacts are sealed within the glass tube with inert gas to maintain contact reliability. n FEATURES (1) Reed contacts are hermetically sealed within a glass tube with inert gas and do not receive any influence from the external atmospheric environment ...
Page 2
... ORD9215 n ELECTRICAL CHARACTERISTICS Parameter Pull-in Value (PI) Drop-out Value (DO) Contact resistance (CR) Breakdown voltage Insulation resistance Electrostatic capacitance Contact rating Maximum switching voltage Maximum switching current Maximum carry current (1) Drop-out Value vs. Pull-in Value Pull-in Value 152 Rated value 10∼50 4min 100max 150min 9 10 min 0 ...
Page 3
... Breakdown voltage DC:V 400 300 200 100 Pull-in Value (5) Electrostatic capacitance pF 0.4 0.3 0.2 0 Pull-in Value (4) Insulation resistance 99 0 (1MHz) ORD9215 (DC 100V) Insulation resistance 153 ...
Page 4
... ORD9215 n OPERATING CHARACTERISTICS Parameter Operate time Bounce time Release time Resonant frequency Maximum operating frequency (1) Operate time (25Hz: 100AT energized) ms 0.5 0.4 0.3 0.2 0 Pull-in Value (3) Release time (25Hz: 100AT energized Drop-out Value 154 Rated value 0.4max 0.4max 0.05max 3700±400 ...
Page 5
... MECHANICAL CHARACTERISTICS (1) Lead tensile test (static load) (2.27kg-10sec) Before test n ENVIRONMENTAL CHARACTERISTICS (1) Temperature characteristics % −10 −20 −30 −40 (2) Lead tensile strength 99 0.1 0 After test − Temperature l ORD9215 10kg Breaking load 100 120 ℃ 155 ...
Page 6
... ORD9215 (2) Temperature cycle (-55℃∼+125 ℃ 100 Before test (4) High temperature storage test (+125℃-500H 100 Before test 156 (3) Temperature and humidity cycle 100 80 60 After test (5) Low temperature storage test 100 80 60 After test - 10℃∼ + 65℃ 80%∼98% ...
Page 7
... Shock test 1) Electrical characteristics (30G: 11ms 100 Before test After test (7) Vibration test (20G: 10∼1000Hz 100 Before test After test 2) Misoperation area (open→close) G 1500 1000 Misoperation area 500 Pull-in Value l ORD9215 157 ...
Page 8
... ORD9215 n LIFE EXPECTANCY DATA: ORD9215 Load conditions Voltage: 5VDC Current: 100mA 1mA , 5mA Load: Resistive load Load conditions Voltage: 12 VDC Current: 5mA, 10mA, 100mA Load: Resistive load Load conditions Voltage: 24 VDC Current: 100mA, 200mA, 400mA Load: Resistive load 158 (%) ...