... REED SWITCH ORD213 Super Ultraminiature n GENERAL DESCRIPTION The ORD213 is a small single-contact reed switch designed for general control of low-level loads less than 24 V. The reed contacts are sealed within the glass tube within inert gas to maintain contact reliability. n FEATURES (1) Reed contacts are hermetically sealed within a glass tube with inert gas and do not receive any influence from the external atmospheric environment ...
Page 2
... ORD213 n ELECTRICAL CHARACTERISTICS Parameter Pull-in Value (PI) Drop-out Value (DO) Contact resistance (CR) Breakdown voltage Insulation resistance Electrostatic capacitance Contact rating Maximum switching voltage Maximum switching current Maximum carry current (1) Drop-out Value vs. Pull-in Value Pull-in Value 48 Rated value 10∼40 5min 200max 150min 9 10 min ...
Page 3
... Breakdown voltage DC:V 400 300 200 100 Pull-in Value (5) Electrostatic capacitance pF 0.4 0.3 0.2 0 Pull-in Value (4) Insulation resistance 99 0 (1MHz ORD213 l (DC 100V Insulation resistance 49 ...
Page 4
... ORD213 n OPERATING CHARACTERISTICS Parameter Operate time Bounce time Release time Resonant frequency Maximum operating frequency (1) Operate time (25 Hz: 100AT energized) ms 0.5 0.4 0.3 0.2 0 Pull-in Value (3) Release time (25Hz: 100AT energized) µ Drop-out Value 50 Rated value 0.3max 0.3max 0.05max 11000±2000 ...
Page 5
... MECHANICAL CHARACTERISTICS (1) Lead tensile test (static load) (2.27kg-10sec 200 150 CR 100 Before test After test n ENVIRONMENTAL CHARACTERISTICS (1) Temperature characteristics % −10 −20 −30 −40 (2) Lead tensile strength 99 0.1 0 − Temperature ORD213 10kg Breaking load 100 120 ℃ 51 ...
Page 6
... ORD213 (2) Temperature cycle (-55°C to 125° 200 150 CR 100 Before test (4) High temperature storage test 200 150 CR 100 Before test 52 (3) Temperature and humidity cycle 200 150 100 After test (5) Low temperature storage test (+125℃-500H 200 150 100 After test -10° ...
Page 7
... Shock test 1) Electrical characteristics (30G: 11ms 200 150 CR 100 Before test After test (7) Vibration test (20G: 10∼1000Hz 200 150 CR 100 Before test After test 2) Misoperation area (open→close) G 1500 1000 Misoperation area 500 Pull-in Value ORD213 ...
Page 8
... ORD213 n LIFE EXPECTANCY DATA: ORD213 Load conditions Voltage: 5VDC Current: 100µA , 1mA , 5mA Load: Resistive load (%) Load conditions Voltage: 12VDC Current: 5mA , 10mA , 100mA Load: Resistive load (%) Load conditions Voltage: 24VDC Current: 1mA , 10mA , 50mA Load: ...