SC-6 Omron, SC-6 Datasheet - Page 3

no-image

SC-6

Manufacturer Part Number
SC-6
Description
CONN CABTIRE CABLE 7.5-9MM DIA
Manufacturer
Omron
Type
Connectorr
Datasheets

Specifications of SC-6

Switch Type
Safety-Door Switch
Operating Temp Range
-30C to 70C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
SC6

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SC-60
Manufacturer:
Cooper/Bussmann
Quantity:
135
Part Number:
SC-60 60A
Manufacturer:
BUSSMANN/巴斯曼
Quantity:
20 000
Part Number:
SC-600
Manufacturer:
SENSORY
Quantity:
20 000
Part Number:
SC-605
Quantity:
5 510
Part Number:
SC-605
Quantity:
5 510
Part Number:
SC-610ALQ48LF
Manufacturer:
SONY
Quantity:
774
Part Number:
SC-610ALQ48LF
Manufacturer:
SENSORY
Quantity:
20 000
D4DS
Specifications
J APPROVED STANDARD RATINGS
TÜV (EN60947-5-1)
Note: Use a 10-A fuse type gl or gG as a short-circuit protection device that conforms to IEC269.
UL (UL508/CSA C22.2 No.14)
A600
J CHARACTERISTICS
Note: 1. Although the Switch casing resists dust, oil, and water, make sure that the keyhole on the head is free from dust, oil, water, and
Utilization category
Rated operating current (I
Rated operating voltage (U
Rated voltage
120 VAC
240 VAC
480 VAC
600 VAC
Degree of protection (see note 1)
Life expectancy (see note 2)
Operating speed
Contact gap
Operating frequency
Positive opening force (see note 3)
Positive opening travel (see note 3)
Insulation resistance
Contact resistance
Dielectric strength
Rated insulation voltage (U
Conditional short-circuit current
Short-circuit protective device (SCPD)
Switching overvoltage
Pollution degree (operating environment)
Conventional enclosed thermal current
(I
Protection against electric shock
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Weight
the
)
2. Life expectancy values are calculated at an operating temperature of 5°C to 35°C, and an operating humidity of 40% to 70%.
3. These figures are minimum requirements for safe operation.
chemical, or the D4DS may wear out, break, or malfunction.
Contact your OMRON sales representative for more detailed information on other operating environments.
Carry current
10 A
e
)
e
i
y
)
)
IP65 (EN60947-5-1)
Mechanical: 1,000,000 operations min.
Electrical: 150,000 operations min.
0.1 m/s to 0.5 m/s
2 x 2.0 mm min.
30 operations/minute min.
58.84 N min.
10 mm min.
100 MΩ min. (at 500 VDC) between terminals of same polarity, between terminals of
different polarity, between each terminal and ground, and between each terminal and
non-current-carrying metal part
25 mΩ max. (initial value)
U
between each terminal and non-current-carrying metal part (EN60947-5-1)
400 V (EN60947-5-1)
100 A (EN60947-5-1)
10 A, fuse type gI or gG (IEC269)
1,500 V max. (EN60947-5-1)
3 (EN60947-5-1)
10 A (EN60947-5-1)
Class II (double insulation)
Malfunction: 10 to 500 Hz, 0.65-mm single amplitude with an imposed acceleration of
100 m/s
Destruction: 1,000 m/s
Malfunction: 300 m/s
Operating: --30°C to 70°C (with no icing)
Operating: 95% max.
Approx. 76 g (for D4DS-15FS)
AC-15
2 A
400 V
Current
Make
60 A
30 A
15 A
12 A
imp
4 kV between terminals of same polarity, between terminals of different polarity, and
2
max.
2
min.
2
4
Break
6 A
3 A
1.5 A
1.2 A
min.
Volt-amperes
Make
7,200 VA
Break
720 VA

Related parts for SC-6