A22-24AG Omron, A22-24AG Datasheet - Page 132

LAMP A22 SERIES 24VAC/DC LED GRN

A22-24AG

Manufacturer Part Number
A22-24AG
Description
LAMP A22 SERIES 24VAC/DC LED GRN
Manufacturer
Omron
Type
Pushbutton Switchr
Datasheets

Specifications of A22-24AG

Accessory Type
LED Lamp Replacement
Color
Green
For Use With/related Products
A22 Series
For Use With
Z1496 - SWITCH PB RND MOM SPST-NO ILLZ1495 - SWITCH PB ILL RND MOM SPST-NOZ1492 - SWITCH PB RND MOM SPST-NC ILLZ1494 - SWITCH PB ILL RND MOM SPST-NOZ1486 - SWITCH PB ILL RND MOM SPST-NOZ1485 - SWITCH PB ILL RND MOM SPST-NOZ1482 - SWITCH PB RND MOM SPST-NC ILLZ1484 - SWITCH PB ILL RND MOM SPST-NOZ1483 - SWITCH PB RND MOM SPST-NO ILLZ1477 - SWITCH PB SQ MOM SPST-NO ILL-YLWZ1476 - SWITCH PB SQ MOM SPST-NO ILL-WHTZ1475 - SWITCH PB SQ MOM SPST-NO ILL-GRNZ1474 - SWITCH PB SQ MOM SPST-NO ILL-BLU
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
A2224AG
Z1577
Precautions
Refer to the Technical Information for Pushbutton Switches (Cat. No. A143) and the Precautions section for the A16.
Mounting
When mounting the Case onto the Socket Unit, ensure that the orien-
tation is correct. Perform mounting with the • mark on the Case and
the TOP mark on the Socket Unit facing in the same direction.
130
Cat. No. A127-E1-03
Correct Use
Case
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
mark
In the interest of product improvement, specifications are subject to change without notice.
Socket Unit
TOP mark
Wiring
When using stranded wire, gather the ends of the strands together
before wiring.
When wiring, insert the wire until it comes into contact with some-
thing. After wiring is completed, pull on the wires to confirm that they
are connected securely.
After wiring, ensure that continuous pressure is not applied to the ter-
minals.
Refer to internal connections diagrams and confirm the terminal
numbers before performing wiring.
Screw-Less Clamps
Mounting Procedure
1. Strip a length of 10 mm off the end of the wire (allowable range:
2. Bunch wire strands together and straighten them.
3. Insert the wire into the insertion hole while pressing the release
4. Let go of the release button to lock the wire into place.
5. After locking, pull on the wire gently to confirm that it is securely
Removing Procedure
Remove wires by pulling them while pressing the release button.
Note: When reusing wires that have already been locked, cut off the
10 1 mm).
button at the side of the hole. (Using a precision screwdriver is
recommended.)
locked.
end of the wire and strip the wire again before using.