VPS-01 Carling Technologies, VPS-01 Datasheet - Page 6

PANEL SEAL FOR ROCKER SWITCH

VPS-01

Manufacturer Part Number
VPS-01
Description
PANEL SEAL FOR ROCKER SWITCH
Manufacturer
Carling Technologies
Type
Contura Connectorsr
Series
VPSr
Datasheets

Specifications of VPS-01

Accessory Type
Panel Seal
Illumination
Not Illuminated
Mounting Style
Panel
For Use With/related Products
Contura Rocker Switches
For Use With
432-1098 - SWITCH ROCKER DPDT 20A SEALED432-1097 - SWITCH ROCKER SPDT 20A SEALED432-1096 - SWITCH ROCKER SPST 20A SEALED432-1095 - SWITCH ROCKER SPST 20A SEALED432-1094 - SWITCH ROCKER SPDT 20A SEALED432-1093 - SWITCH ROCKER SP3T 20A SEALED432-1092 - SWITCH ROCKER SPDT 20A SEALED432-1091 - SWITCH ROCKER SPDT 20A SEALED432-1090 - SWITCH ROCKER SPDT 20A SEALED432-1089 - SWITCH ROCKR SPST 12V 20A SEALED432-1088 - SWITCH ROCKR SPST 12V 20A SEALED
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
432-1101
999-16543-1
48
1
Series
V
2 CIRCUIT
Terminal Connections as viewed
from bottom of switch:
8 terminal 10 terminal
8 - - 7
1 - - 4
2 - - 5
3 - - 6
Position:
SP
1
2
3
4
5
6
7
8
SPECIAL CIRCUITS
H*
G*
S
M*
R
E*
*Jumper between terminals 2 & 5 for circuits H, G, & M are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E
may be used for SP OFF-ON-ON circuit. Circuits H, M & E not available with ratings 5 - 9.
3 RATING
1
4
5
8* 10A 250VAC, 15A 125VAC, 1/2 HP 125-250VAC, 12(2)A 250 VAC µ T85
9* 10A 250VAC, 15A 125VAC, 1/2 HP 125-250 VAC, 12(6)A 250 VAC T85
B 15A 24V
C 20A 18V
D 20A 12V
* Ratings 8 & 9 are UL, CSA, VDE, DEMKO, SEMKO, NEMKO, FIMKO & BEAB certified,
require terminations A or B for double pole circuits, & are not available with illumination cir-
cuits 4, 8, D, J, N, & T or with wire lead or solder lug terminations. Circuits 1, 4, A & D are
not available with rating 8. Ratings 8 & 9 must specify lamp code 2 (250VAC neon).
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch.
Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed Lamps when Illuminated
S
A
B
C
D
E
F
G
H
U
Selections for Single Pole Switches Only:
J
K
Selections for Double Pole Switches Only:
L
M
N
P
U
8 term
1
A
J
3
C
5
E
Note: Codes J & K for circuits H, G & M. Ratings 8 & 9 require terminations A or B only.
5 ILLUMINATION & SWITCH SEALING
1 SERIES
V
4 TERMINATION/BASE STYLE
.4VA @ 28VDC Resistive
10A 250VAC 1/2 HP, 15A 125VAC 1/2 HP, No Listings
10A 250VAC 1/2 HP, 15A 125VAC 1/2 HP, UL Recognized, CSA Certified
DP
A
B
C
D
F
J
K
L
Carling
Technologies
2
Circuit
10 term
2
B
K
4
D
6
F
0
1
2
3
4
7
Z
Y
8
W
9
R
T
V
Y
5
6
3,5
10 - - 9
1 D A B
8 - - 7
1 - - 4
2 - - 5
3 - - 6
(2 & 3, 5 & 6)
(2 & 3, 5 & 6)
2 & 3, 5 & 6
2 & 3, 5 & 6
2 & 3, 5 & 6
2 & 3
5 & 6
(ON)
(ON)
3
Rating
ON
ON
ON
ON
ON
ON
Termination
.250 TAB (QC) no barriers
.250 TAB (QC) with barriers
.250 TAB (QC) no barriers
Solder Lug no barriers
Solder Lug
Wire Leads no barriers
Wire Leads
None
# 1
# 1
# 2
# 1
&# 2
# 1
& # 2
# 1
# 1
& # 2
# 2
# 1
& # 2
# 1
& # 2
# 1
& # 2
# 1
# 2
# 1
& # 2
# 1
& # 2
# 1
& # 2
1
& # 2
Actuator Lens position
Independent
Down
Up
Down
Down
Up
Independent
Up
Independent
Up
Independent
Independent
Independent
Down
Independent
Independent
Independent
Down
Up
Down
Down
Up
Up
Independent
Independent
Up
4
Termination
Connected Terminals
( ) - momentary
SP - single pole - uses terminals 1, 2 & 3.
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7, 8, 9 & 10 for lamp circuit only.
2 & 3, 5 & 4
NONE
NONE
NONE
NONE
NONE
2 & 3
2 & 3
2 & 3
2 & 3
5 & 3
OFF
OFF
OFF
2
5
Illumination
6
Lamp
T 0 B
1 & 2, 4 & 5
Jumper
No
No
Yes T2 to 5
No
No
No
No
Lamp wired to
Terminals
8+
3+
3+
3+
1+
1+
3+
8+
3+
8+
3+
8+
8+
10+ 9-
3+
6+
8+
6+
3+
3+
3+
1+
1+
3+
8+
10+ 9-
(OFF)
5 & 4
1 & 2
1 & 2
5 & 1
(ON)
(ON)
(ON)
OFF
OFF
OFF
OFF
ON
ON
3
7-
7-
7-
7-
7-
7-
7-
7-
6-
7-
7-
7-
7-
8-
7-
7-
7-
6-
6-
6-
4-
4-
6-
7-
www.carlingtech.com
7
Lamp
8
Bracket
V-Series Contura II & III Sealed Rocker Switches
NOTES
Consult factory to verify horsepower rating for your particular circuit choice.
1
2
3
4
5
-
MC
ARCMC-100
Actuator orientation above terminals:
00
(used with codes 11-18 in selection 12) Selection 14 required when switch requires two
legends. If the two legends consist of one lens and one body legend, lens legend must
be specified in selection 12; body legend specified in selection 14.
For legend options & codes, see page 69 of this catalog
6,7 LAMP ( same coding for both selections)
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
No lamp
Neon
Incandescent 4 3V
LED *
2VDC
6VDC
12VDC
24VDC
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
8 FLUSH BRACKET COLOR
No Seal
One Seal
9 ACTUATOR
No Actuator
Contura II
Contura III
10 LENS
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
0 - No Actuator
Clear
1
2
3
Square lens options available only for Contura II:
4
5
11 ACTUATOR COLOR
0 - No Actuator
Soft Surface
Hard Surface
12 ACTUATOR LENS OR BODY LEGENDS
13 LEGEND ORIENTATION
0
1
2
3
4
14 ACTUATOR LENS LEGEND
00 - No Legend this location/No actuator
11 ON
15 O O 16
For additional legend options & codes, see page 69 of this catalog
9
Actuator
Custom colors are available. Consult factory.
Body legends not available on Soft surface actuators; White imprinting is standard on
black actuators; Black imprinting is standard on white, red and gray actuators; Custom
colors are available, consult factory.
Additional ratings available. See page 57.
Contura II available with two square lenses. Consult factory for details.
Rating 9 only available with circuits 1, 4, A & D.
OFF
A R B
F N
F
AC
AZCAC-100
No legend
Orientation 1
Orientation 2
Orientation 3
Orientation 4
No legend this location / no actuator
4
12 OFF
10
Lens
0
1 125VAC 2 250VAC
Red
A
B
C
D
Black
B
C
0
A
B
C
D
White
6
7
8
9
A
E3
E5
A9CE3-1E5
ON
O O 17 O I
N F
SLEEPER
LIGHTS
(used with codes 11-18 in selection 12)
F
Black
B
C
13
1
11
Color
AND TEXTURE
5 6V
Amber
L
M
N
P
White
W
Y
Z - No Lens
Amber
B
C
D
E
F
A9C45-200
O
I
45
1
, PANEL SEAL
3,6
2
Gray
G
H
14
18 I O
12
Legend
1,4
00
6 12V
superbright superbright
Green
F
G
H
J
Gray
G
H
Green
G
H
J
K
L
O
I
ORIENTATION 4
Red
R
S
2
-
7 18V
Red
R
S
T
V
Red
M
N
P
R
S
13
Legend
Orientation
White
W
Y
0
ORIENTATION 3
ACTUATOR/LENS IN PANEL
ORIENTATION 1
ORIENTATION OF
8 24V
Blue
T
U
V
W
Y
14
Actuator
Lens Legend
00
ORIENTATION 2

Related parts for VPS-01