SDPGB-30+100PG5 Honeywell Sensing and Control, SDPGB-30+100PG5 Datasheet - Page 2

no-image

SDPGB-30+100PG5

Manufacturer Part Number
SDPGB-30+100PG5
Description
SENSOR PRESS GAUGE DIG 100PSI
Manufacturer
Honeywell Sensing and Control
Series
SDPGBr
Datasheet

Specifications of SDPGB-30+100PG5

Rohs Status
RoHS non-compliant
Pressure Type
Gauge
Operating Pressure
100 PSI
Port Size
Male, 1/4" (6.35mm) NPT
Output
Digital
Operating Temperature
-20°C ~ 85°C
Package / Case
3.38" x 2.88" x 1.65" (85.85mm x 73.15mm x 41.91mm)
Other names
287-1928
SDPGB-30+100GP5
SDPGB-30I+100PG5
S D P G B S e r i e s
SenSym ICT Part No.
Characteristic
Accuracy
Temperature Stability
Display
Controls & Location
Auto Shut-off Time
Battery and Battery Life
Low Battery Indication
Environmental Specifications
Mechanical Specifications
PRESSURE RANGE AND RESOLUTION SPECIFICATIONS
SDPGB SERIES ELECTRICAL CHARACTERISTICS
DIGITAL PRESSURE GAUGE CHARACTERISTICS
SDPGB-30+100PG5
SDPGB0015PG5
SDPGB0030PG5
SDPGB0100PG5
SDPGB0200PG5
SDPGB0300PG5
SDPGB0500PG5
SDPGB1000PG5
(linearity, hysteresis, repeatability)
(relative to 25°C)
(update rate, type, size)
Size
Weight (approximate)
Material & Color
Pressure/Vacuum Connection and Material
Media Compatibility
Storage temperature
Operating temperature
Compensated temperature
3.38"W x 2.88"H x 1.65"D
(not including pressure fitting)
Add approximately 0.75" to height for pressure fitting
Gauge: 9 ounces
Shipping weight: 1 pound
Extruded aluminum case, epoxy powder coated
Polycarbonate cover, front and rear gaskets
Light gray body, light gray/blue front
1/4" NPT male, 316 stainless steel
All wetted parts are 316 SS
Compatible with most liquids and gases
-30.0 inHg/100.0 psig
100.0 psig
199.9 psig
1000 psig
Pressure
15.0 psig
30.0 psig
300 psig
500 psig
Range
1 408 954 6700
FAX: 408 954 9458
SenSym ICT
1804 McCarthy Boulevard
Milpitas, CA 95035
www.sensym-ict.com
±0.25% of full scale ±1 least significant
digit typical
±1% FS for offset and span,
0 to 70°C typical
3 readings per second nominal
display update rate
3-1/2 digit LCD, 1/2" digit height
Front-accessible potentiometers,
non-interactive zero and span
Front push button turns gauge on or off.
When on auto shut-off timer starts
5 minutes
Two AA alkaline, approx. 2500 hours
“LOBAT” on display when battery
must be replaced
–40° to +95°C
–20° to +85°C
Resolution
0.01 psig
0.1 psig
0.1 psig
0.1 psig
0.1 psig
0° to +70°C
1 psig
1 psig
1 psig
Pressure
Rated
Proof
2x
2x
2x
2x
2x
2x
2x
2x
GENERAL DISCLAIMER: Invensys Sensor Systems reserves the right to make changes to its
products and their specifications at any time, without prior notice to anyone. Invensys Sensor
Systems has made every effort to ensure accuracy of the information contained herein but can
assume no responsibility for inadvertent errors, omissions, or subsequent changes. Invensys Sensor
Systems does not assume any responsibility for the use of any circuit or other information described
within this document, and further, makes no representations of any kind that the circuit and
information described herein is free of infringement of any intellectual property right or any other
right of third parties. No express or implied licenses of any Invensys Sensor Systems intellectual
property right is granted by implication or otherwise.
Pressure
Rated
Burst
4x
4x
4x
4x
4x
4x
4x
4x
SenSym ICT maintains a constant effort to upgrade and improve its products,
therefore specifications are subject to change.
Installation
Tighten the gauge by using the wrench on hex
fitting only. Do not tighten it by turning housing!
Use fittings designed for the pressure range of
the gauge. Do not apply vacuum to gauges not
designed for vacuum operation.
Operation
Press the round button on the front of the gauge
to activate the display. The gauge will stay on for
5 minutes. After this time, the gauge will
automatically shut off. The gauge can be shut off
at any time by pressing the button again.
“LOBAT” will appear in the upper left-hand corner
of the display when the battery voltage falls
sufficiently. The battery should be replaced soon
after the LOBAT indicator comes on or unreliable
readings may result.
Calibration
Remove the calibration potentiometer cover on
the front of the unit to access the Zero and Span
controls. The Zero and Span controls are non-
interactive. The gauge port must be open to the
ambient with no pressure or vacuum applied.
Adjust the Zero control until the gauge reads zero
with the minus (–) sign occasionally flashing.
Span calibration should only be attempted if the
user has access to a pressure reference of known
accuracy. The accuracy of the calibration
equipment ideally should be at least four times
the gauge accuracy. Zero calibration must be
done before span calibration. Record readings at
three to five points over the range of gauge and
adjust span control to minimize error and meet
specifications.
Battery Replacement
Remove the six phillips head screws on the back
of the unit. Carefully remove batteries from the
holders by lifting up the positive end of the
battery (opposite the spring). Take care not to
bend or distort the battery retention springs. DO
NOT discard the old battery into fire, any other
sources of extreme heat, or in any other
hazardous manner. Always replace both batteries
at the same time with high quality alkaline
batteries. Observe the polarity of the batteries
when replacing them. The negative (flat) end of
each battery should be inserted first and should
face the spring in the battery holder. Replace the
back cover, including the rubber sealing gasket.
1
/
4
"NPT
Span
Made in USA
SenSym ICT
3.38"
PSIG
.75"
Zero
2.88"
1.65"
© Copyright 09/01
Tighten
at hex
fitting
only

Related parts for SDPGB-30+100PG5