MP3V5004GC6U Freescale Semiconductor, MP3V5004GC6U Datasheet - Page 2

IC PRESSURE SENSOR 8-SOP

MP3V5004GC6U

Manufacturer Part Number
MP3V5004GC6U
Description
IC PRESSURE SENSOR 8-SOP
Manufacturer
Freescale Semiconductor
Type
Gager
Datasheet

Specifications of MP3V5004GC6U

Pressure Type
Gauge
Operating Pressure
0.57 PSI, 3.92 kPa
Port Size
Male, 0.12" (3mm) OD
Output
0.6 ~ 3 V
Voltage - Supply
2.7 V ~ 3.3 V
Termination Style
PCB
Operating Temperature
0°C ~ 85°C
Package / Case
8-SOP Axial Port
Mounting
Surface Mount
Pin Count
8
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Package Type
SMT
Operating Supply Voltage (typ)
3V
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.3V
Output Type
Analog
Mounting Style
SMD/SMT
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
0 C
Supply Voltage (min)
2.7 VDC
Supply Voltage (max)
3.3 VDC
Supply Current
10 mA
Operating Pressure Range
0 To 3.92kPa
Connection Size
0.125"
Sensitivity, V/p
0.6V/kPa
Sensor Case Style
SOP
No. Of Pins
8
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MP3V5004GC6U
Manufacturer:
FREESCALE
Quantity:
20 000
Table 1. Operating Characteristics (V
MP3V5004G
2
Operating Characteristics
Pressure Range
Supply Voltage
Supply Current
Span at 306 mm H
Offset
Sensitivity
Accuracy
1. Device is ratiometric within this specified excitation range.
2. Span is defined as the algebraic difference between the output voltage at specified pressure and the output voltage at the minimum rated
3. Offset (V
4. Accuracy (error budget) consists of the following:
5. Auto-Zero at Factory Installation: Due to the sensitivity of the MP3V5004G, external mechanical stresses and mounting position can affect
pressure.
Linearity:
Temperature Hysteresis: Output deviation at any temperature within the operating temperature range, after the temperature is cycled to and
Pressure Hysteresis:
Offset Stability:
TcSpan:
TcOffset:
Variation from Nominal:
the zero pressure output reading. Auto-zeroing is defined as storing the zero pressure output reading and subtracting this from the device's
output during normal operations. Reference AN1636 for specific information. The specified accuracy assumes a maximum temperature
change of ±5°C between auto-zero and measurement.
Pressure
(3) (4)
(4) (5)
off
) is defined as the output voltage at the minimum rated pressure.
(1)
2
O (3 kPa)
Characteristic
(2)
Output deviation from a straight line relationship with pressure over the specified pressure range.
from the minimum or maximum operating temperature points, with zero differential pressure applied.
Output deviation at any pressure within the specified range, when this pressure is cycled to and from the minimum
or maximum rated pressure, at 25°C.
Output deviation, after 1000 temperature cycles, -30° to 100°C, and 1.5 million pressure cycles, with minimum
rated pressure applied.
Output deviation over the temperature range of 10° to 60°C, relative to 25°C.
Output deviation with minimum rated pressure applied, over the temperature range of 10° to 60°C, relative to 25°C.
The variation from nominal values, for Offset or Full Scale Span, as a percent of V
100 to 400 mm H
0 to 100 mm H
S
= 3.0 Vdc, T
2
2
O (10 to 60°C)
O (10 to 60°C)
A
= 25°C unless otherwise noted, P1 > P2.
Symbol
P
V
V
V/P
V
OP
FSS
OFF
I
S
S
Min
0.45
2.7
0
Typ
3.0
1.8
0.6
0.6
5.9
FSS
Freescale Semiconductor
, at 25°C.
Max
3.92
0.75
±1.5
±2.5
400
3.3
10
mV/mm H
mm H
%V
%V
V/kPa
mAdc
Sensors
Unit
kPa
V
V
V
DC
FSS
FSS
2
O
2
O

Related parts for MP3V5004GC6U