SENSOR PRESSURE ABSOLUTE 8-SSOP

MPXH6250A6T1

Manufacturer Part Number
MPXH6250A6T1
Description
SENSOR PRESSURE ABSOLUTE 8-SSOP
Manufacturer
Freescale Semiconductor
Series
MPXH6250r
Datasheet

Specifications of MPXH6250A6T1

Pressure Type
Absolute
Operating Pressure
3 ~ 36 PSI
Output
0 ~ 4.9V
Voltage - Supply
4.85 V ~ 5.35 V
Termination Style
PCB
Operating Temperature
-40°C ~ 125°C
Package / Case
8-SSOP without Port
Mounting Style
SMD/SMT
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
5.1 V
Output Voltage
4.826 V to 4.966 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
MPXH6250A
2
Operating Characteristics
Table 1. Operating Characteristics (V
Pressure Range
Supply Voltage
Supply Current
Minimum Pressure Offset
Full Scale Output
Full Scale Span
Accuracy
Sensitivity
Response Time
Warm-Up Time
Offset Stability
1. Device is ratiometric within this specified excitation range.
2. Offset (V
3. Full Scale Output (V
4. Full Scale Span (V
5. Accuracy is the deviation in actual output from nominal output over the entire pressure range and temperature range as a percent of span
6. Response Time is defined as the time for the incremental change in the output to go from 10% to 90% of its final value when subjected to a
7. Warm-up Time is defined as the time required for the product to meet the specified output voltage after the Pressure has been stabilized.
8. Offset Stability is the product's output deviation when subjected to 1000 hours of Pulsed Pressure, Temperature Cycling with Bias Test.
minimum rated pressure.
at 25°C due to all sources of error including the following:
Linearity: Output deviation from a straight line relationship with pressure over the specified pressure range.
Temperature Hysteresis: Output deviation at any temperature within the operating temperature range, after the temperature is cycled to and
from the minimum or maximum operating temperature points, with zero differential pressure applied.
Pressure Hysteresis: Output deviation at any pressure within the specified range, when this pressure is cycled to and from the minimum or
maximum rated pressure, at 25°C.
TcSpan: Output deviation over the temperature range of 0 to 85°C, relative to 25°C.
TcOffset: Output deviation with minimum rated pressure applied, over the temperature range of 0 to 85°C, relative to 25°C.
Variation from Nominal: The variation from nominal values, for Offset or Full Scale Span, as a percent of V
specified step change in pressure.
Pressure
@ V
@ V
@ V
S
S
S
(5)
= 5.1 Volts
= 5.1 Volts
= 5.1 Volts
off
) is defined as the output voltage at the minimum rated pressure.
(8)
(1)
(7)
(6)
(2)
(3)
(4)
FSS
FSO
) is defined as the algebraic difference between the output voltage at full rated pressure and the output voltage at the
Characteristic
) is defined as the output voltage at the maximum or full rated pressure.
S
= 5.1 Vdc, T
(0 to 85°C)
(0 to 85°C)
(0 to 85°C)
(0 to 85°C)
A
= 25°C unless otherwise noted, P1 > P2.)
Symbol
V
V
P
V
V/P
V
FSO
FSS
t
I
OP
R
o
off
S
0.133
4.826
4.552
4.74
Min
20
±0.25
0.204
4.896
4.692
20.4
Typ
5.1
6.0
1.0
20
20
FSS
Freescale Semiconductor
, at 25°C.
0.274
4.966
4.833
Max
5.46
±1.5
250
10
mV/kPa
%V
%V
Sensors
mAdc
Unit
kPa
Vdc
Vdc
Vdc
Vdc
ms
ms
FSS
FSS