MPXM12GS Freescale Semiconductor, MPXM12GS Datasheet - Page 3

no-image

MPXM12GS

Manufacturer Part Number
MPXM12GS
Description
IC PRESSURE SENSOR 5-MPAK
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MPXM12GS

Pressure Type
Gauge
Operating Pressure
1.45 PSI
Port Size
Male, 0.117" (2.97mm) Tube
Output
0 ~ 55mV
Voltage - Supply
6V
Termination Style
PCB
Operating Temperature
-40°C ~ 125°C
Package / Case
MPAK (4 leads + Tab) with Port
Mounting Style
SMD/SMT
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Supply Voltage (max)
6 VDC
Supply Current
6 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Sensors
Freescale Semiconductor
Operating Characteristics
Table 1. Operating Characteristics (V
Differential Pressure Range
Supply Voltage
Supply Current
Full Scale Span
Offset
Sensitivity
Linearity
Pressure Hysteresis
Temperature Hysteresis (–40°C to +125°C)
Temperature Coefficient of Full Scale Span
Temperature Coefficient of Offset
Temperature Coefficient of Resistance
Input Impedance
Output Impedance
Response Time
Warm-Up Time
Offset Stability
1. 1.0 kPa (kiloPascal) equals 0.145 psi.
2. Device is ratiometric within this specified excitation range. Operating the device above the specified excitation range may induce additional
3. Full Scale Span (V
4. Offset (V
5. Response Time is defined as the time form the incremental change in the output to go from 10% to 90% of its final value when subjected to
6. Warm-up Time is defined as the time required for the product to meet the specified output voltage after the pressure is stabilized.
7. Offset stability is the product’s output deviation when subjected to 1000 hours of Pulsed Pressure, Temperature Cycling with Bias Test.
error due to device self-heating.
minimum related pressure.
a specified step change in pressure.
(4)
OFF
(7)
(2)
(6)
(3)
(5)
) is defined as the output voltage at the minimum rated pressure.
(10% to 90%)
(6)
FSS
(0 to 10 kPa)
) is defined as the algebraic difference between the output voltage at full rated pressure and the output voltage at the
(1)
Characteristic
S
= 3.0 Vdc, T
A
= 25°C unless otherwise noted, P1 > P2)
Symbol
TCV
TCV
ΔV/ΔP
V
TCR
P
Z
V
V
Z
FSS
t
I
OP
out
off
R
o
in
S
FSS
off
–0.22
–0.5
0.21
Min
400
750
45
0
0
±0.1
±0.5
±0.5
Typ
±15
3.0
6.0
5.5
1.0
55
20
20
–0.16
1250
Max
0.27
550
6.0
5.0
10
70
35
Pressure
%V
mV/kPa
%Z
%V
%V
%V
%V
mAdc
μV/°C
Unit
kPa
Vdc
mV
mV
MPX12
FSS
ms
ms
Ω
Ω
in
FSS
FSS
FSS
FSS
/°C
/°C
3

Related parts for MPXM12GS