MG-75-B-MD SSI Technologies Inc, MG-75-B-MD Datasheet - Page 3

no-image

MG-75-B-MD

Manufacturer Part Number
MG-75-B-MD
Description
SENSOR 75 PSI 4-20 MA 1/8 NPT
Manufacturer
SSI Technologies Inc
Series
MG-MDr
Datasheet

Specifications of MG-75-B-MD

Pressure Type
Gauge
Operating Pressure
75 PSI
Port Size
Male, 1/8" (3.175mm) NPT
Output
LCD Display
Accuracy
±0.25%
Voltage - Supply
12V
Operating Temperature
-10°C ~ 60°C
Package / Case
Stainless Steel
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
The
programmable pressure set points – a low limit set point
and high limit set point. These set points control the limit
switch (NPN transistor output).
To understand the high and low pressure set points
functioning, let’s look at a typical application where the
MediaGauge™ MG-MD in used in a monitor and control
system.
In the example shown above, the MediaGauge MG-MD is
attached to an external power supply, a current meter and a
relay. We will assume the low set point has been set to 100
psi and the high set point has been set to 375 psi.
SSI TECHNOLOGIES, INC.
Controls Division
2643 West Court Street
Janesville, WI 53548-5011
Phone: (608)758-1500
Fax: (608)758-2491
www.ssitechnologies.com
MediaGauge ™
4 Pin Mini DIN
Example Using High & Low Set Points
1
2
3
4
MediaGauge™
Supply Source
(White)
4 - 20 mA OUT
(Blue)
Switch Output
(Brown)
Ground
(Black)
MediaGauge™ (Model MG-MD) Digital Pressure Gauge
VCC
Meter
SSI Technologies – Application Note PS-AN7
MG-MD
RELAY
also
has
NO
COM
two
Product Overview
NC
keypad
3
In the graph shown here, you can see how the user can
program the high and low set points to control when the
relay would turn on and off.
Input pressure values below the low limit set point or higher
than the high limit set point will result in a limit switch output
(Brown Wire) of 0 Vdc.
Input pressure values within the control set point limits
(between the low and high set point values) will result in a
limit switch output that follows the external power source.
Note: The 4-20 mA output (Blue Wire) is proportional to the
input pressure and operates independent of these low and
high set points.
VCC
Limit Switch Operation
Copyright January 30, 2009
SSI Technologies Inc.
All Rights Reserved
Revision 4
RoHS

Related parts for MG-75-B-MD