Page 1
... Thus, for many applications no trimming networks are required in the signal ELECTRICAL CONNECTION Bottom view Note: The polarity indicated is for pressure applied to port B (for absolute devices pressure is applied to port A and the output polarity is reversed.) SCX Series Scale ½ ...
Page 2
... PRESSURE SENSOR CHARACTERISTICS STANDARD PRESSURE RANGES Part Number Operating pressure SCX01DN SCX05DN SCX15AN SCX15DN SCX30AN SCX30DN SCX100AN SCX100DN SCX150DN Maximum ratings (for all devices) Supply voltage V S Common-mode pressure Lead temperature (soldering, 4 seconds) COMMON PERFORMANCE CHARACTERISTICS Characteristic Zero pressure offset 12 4 Combined linearity and hysteresis Temperature effect on span (0 - 70° ...
Page 3
... Vacuum reference (absolute device) Absolute sensors have a hermetically sealed vacuum reference chamber. The offset voltage on these units is therefore measured at vacuum, 0 psia. Since all pressure is measured relative to a vacuum reference,all changes in barometric pressure or changes in altitude will cause changes in the device output. August 2005 / 053 ...
Page 4
... Sensym sales office or the Sensym factory. Low pressure applications For sensing pressures below 1 psi, the circuit shown in Figure A uses the SCX01DN to provide output for inch of water column input pressure. This output signal is compatible with many A/D converters and hence can be used to interface to a microprocessor system ...
Page 5
... Repeat procedure if necessary. * For timing specifications and bus interface, see the ADC0804 Datasheet from National Semiconductor. Figure A. Low pressure circuits provide output for a 0-10 in. W.C. pressure input August 2005 / 053 Precision compensated pressure sensors (cont.) Serial A/D conversion The circuit shown in Figure D is similar to that shown in Figure C, except the output is bit serial ...
Page 6
... SCX Series Precision compensated pressure sensors Figure B. Medical application circuit provide a 0.5 to 3.5 V output for a 0-300 mmHg pressure input Figure C. 6/10 A parallel A/D conversion circuit for 0-1 psig applications August 2005 / 053 www.sensortechnics.com ...
Page 7
... Figure D. Serial A/D conversion for 0-1 psig applications and simple test circuit August 2005 / 053 Precision compensated pressure sensors www.sensortechnics.com SCX Series 7/10 ...
Page 8
... low state (0.0 V). 8/10 Figure E. Timing diagram PORTABLE PRESSURE METER The circuit shown in Figure 200 millibar portable pressure meter. The 3 circuit operates from a single 9 V battery and draws approximately 4.5 mA supply current. This will provide a typical battery life in excess of 100 hours ...
Page 9
... August 2005 / 053 Precision compensated pressure sensors Figure F. 0.5 psi switch Figure 200 millibar meter. SCX Series 9/10 www.sensortechnics.com ...
Page 10
... To order, use the following part number(s) Part number SCX01DN SCX05DN SCX15AN SCX15DN SCX30AN 6-pin right angle socket SCX30DN SCX100AN SCX100DN SCX150DN dimensions in inches (mm) Mounting accessories Description Part number Xmas tree clip SCXCLIP SCXCNCT Pressure tubing clamp SCXSNP1 August 2005 / 053 www.sensortechnics.com ...