SSCSANN005PGAA3 Honeywell Sensing and Control, SSCSANN005PGAA3 Datasheet

SENSOR PRESS 5PSI GAGE 3.3V SIP

SSCSANN005PGAA3

Manufacturer Part Number
SSCSANN005PGAA3
Description
SENSOR PRESS 5PSI GAGE 3.3V SIP
Manufacturer
Honeywell Sensing and Control
Series
TruStability™r
Datasheet

Specifications of SSCSANN005PGAA3

Pressure Type
Gauge
Operating Pressure
0 ~ 5 PSI
Output
ANALOG
Accuracy
±0.35%
Voltage - Supply
3 V ~ 3.6 V
Termination Style
PCB
Operating Temperature
-40°C ~ 85°C
Package / Case
4-SIP Single Port
Operating Pressure Range
0 To 5psi
Sensor Output
Analog
Supply Current
3mA
Voltage Rating
3.3V
Port Style
Axial
Pressure Measurement Type
Gage
Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Installation Instructions for the
TruStability
Silicon Pressure Sensors, Analog Output
GENERAL INFORMATION
TruStability™ High Accuracy Silicon Ceramic (HSC) Series
and Standard Accuracy Silicon Ceramic (SSC) Series s are
piezoresistive silicon pressure sensors offering a ratiometric
analog output for reading pressure over the specified full scale
pressure span and temperature range. They are available in
standard pressure ranges from 1 psi to 150 psi (60 mbar to
10 bar) and are intended for use with non-corrosive, non-ionic
gases, such as air and other dry gases. The liquid media
option extends the performance of these sensors to con-
corrosive, non-ionic liquids.
LIQUID MEDIA OPTION
Table 2. Absolute Maximum Ratings
Sensing and Control
CAUTION
PRODUCT DAMAGE
• Ensure liquid media is applied to Port 1 only; Port 2 is not
• Ensure liquid media contains no particulates. All
• Recommend that the sensor be positioned with Port 1
• Ensure liquid media does not create a residue when dried;
• Ensure liquid media are compatible with wetted materials.
Failure to comply with these instructions may result in
product damage.
Parameter
Supply voltage
Voltage on output pin
ESD susceptibility (human body model)
Storage temperature range
Soldering times and temperature:
Lead solder (SIP, DIP)
Peak reflow (SMT)
compatible with liquids.
TruStability
can accumulate inside the sensor, causing damage or
affecting sensor output.
facing downwards; any particulates in the system are less
likely to enter and settle within the pressure sensor if it is
in this position.
build-up inside the sensor may affect sensor output.
Rinsing of a dead-ended sensor is difficult and has limited
effectiveness for removing residue.
Non-compatible liquid media will degrade sensor
performance and may lead to sensor failure.
®
sensors are dead-ended devices. Particulates
HSC Series and SSC Series
2
-40 [-40]
Min.
-0.3
-0.3
3
SOLDERING
See soldering times and temperatures in Table 2.
CLEANING
Table 1. Environmental Specifications
CAUTION
IMPROPER CLEANING
• Ensure cleaning fluids, such as appropriate alcohols or
• Do not immerse the sensor.
Failure to comply with these instructions may result in
product damage.
Parameter
Humidity:
Vibration
Shock
Life
Solder reflow
Dry gases only
Liquid media option
fluorinated solvents, are used based on the type of
contaminants to be removed.
1
15 s max. at 250 °C [482 °F]
4 s max. at 250 °C [482 °F]
Vsupply + 0.3
85 [185]
Max.
Characteristic
0% to 95% RH, non-condensing
100% condensing or direct liquid
media on Port 1
MIL-STD-202F, Curve AK (20.7 g
random)
MIL-STD-202F, Method 213B,
Condition F
1 million cycles minimum
J-STD-020-C
6.0
-
50044172
ISSUE 4
°C [°F]
Unit
kV
V
V

Related parts for SSCSANN005PGAA3

SSCSANN005PGAA3 Summary of contents

Page 1

... Recommend that the sensor be positioned with Port 1 facing downwards; any particulates in the system are less likely to enter and settle within the pressure sensor this position. • Ensure liquid media does not create a residue when dried; build-up inside the sensor may affect sensor output. ...

Page 2

... The operating temperature range is the temperature range over which the sensor will produce an output proportional to pressure but may not remain within the specified performance limits. 7. Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25 °C [77 °F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability. 8. ...

Page 3

... TruStability HSC Series and SSC Series, Analog Output Figure 1. DIP Pressure Port Dimensional Drawings (For reference only: mm [in]) DIP NN: No ports DIP LN: Single axial barbless port DIP RR: Dual radial barbed ports, same side Issue 4 DIP AN: Single axial barbed port DIP RN: Single radial barbed port ...

Page 4

... TruStability HSC Series and SSC Series, Analog Output Figure 2. SMT Pressure Port Dimensional Drawings (For reference only: mm [in]) SMT NN: No ports SMT LN: Single axial barbless port SMT RR: Dual radial barbed ports, same side 4 Honeywell • Sensing and Control Issue 4 SMT AN: Single axial barbed port ...

Page 5

TruStability HSC Series and SSC Series, Analog Output Figure 3. SIP Package Dimensional Drawings (For reference only: mm [in]) SIP NN: No ports SIP AN: Single axial barbed port SIP FF: Fastener mount, dual axial barbed ports, opposite sides ...

Page 6

TruStability HSC Series and SSC Series, Analog Output Figure 3. SIP Package Dimensional Drawings (continued) SIP GN: Ribbed fastener mount, single axial barbed port 27,96 [1.101] 21,60 [0.850] SIP NB: Fastener mount, dual axial ports, same side SIP RN: ...

Page 7

TruStability HSC Series and SSC Series, Analog Output Figure 3. SIP Package Dimensional Drawings (continued) SIP DR: Dual radial barbed ports, opposite side 15,8 [0.62] 10,0 6,16 [0.39] [0.243] 10,0 [0.39] PORT 1 PORT 2 15,2 [0.60 ...

Page 8

TruStability HSC Series and SSC Series, Analog Output WARNING PERSONAL INJURY • DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure ...

Related keywords