E8EB-NOC2B Omron, E8EB-NOC2B Datasheet - Page 8

no-image

E8EB-NOC2B

Manufacturer Part Number
E8EB-NOC2B
Description
SENSOR PRESSUR 1-5V 0-98KPA NPN
Manufacturer
Omron
Series
E8EBr
Datasheet

Specifications of E8EB-NOC2B

Pressure Type
Gauge
Operating Pressure
-14.50 ~ +0 PSI, -100 ~ 0 kPa
Port Size
Female, 1/8" (3.175mm) NPN
Output
1 ~ 5V
Voltage - Supply
24V
Termination Style
Cable
Operating Temperature
-10°C ~ 55°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E8EBNOC2B
General Precautions
These products cannot be used in safety devices for
presses or other safety devices used to protect
human life. These products are designed for use in
applications for sensing workpieces and workers
that do not affect safety.
Withstand Pressure
Do not apply a pressure higher than the rated withstand pressure.
Applying a pressure higher than this may cause damage.
Operating Environment
Do not use the products in an environment where there are explosive
or inflammable gases.
Power Supply Voltage
Do not use a voltage that exceeds the power supply voltage range.
Using a voltage that exceeds the range may cause burning.
Load Short-circuiting
Do not short-circuit the load. Doing so may cause explosion or
burning.
Incorrect Wiring
Be sure that the power supply polarity and other wiring is correct.
Incorrect wiring may cause explosion or burning.
Precautions for Safe Use
http://www.ia.omron.com/
WARNING
For precautions on individual products, refer to the Safety Precautions in the individual product information.
Pressure Sensors Technical Guide
• When using a Sensor that supports non-corrosive gas as the
• Do not insert any wire or other object into the pressure port. Doing
• Do not use the Sensor alongside high-voltage lines or power lines.
• Mount the Sensor so that it is not subject to ultrasonic vibration.
• Do not apply a tensile force higher than 30 N to the cable or
• The cable can be extended to a maximum of 10 m. For details, see
applicable fluid, use an air filter to remove moisture and oil from the
gas.
so may damage the pressure elements and cause a malfunction.
connector.
the output impedance section on the previous page.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Precautions for Correct Use
C-1