ZSE30-N7L-65 SMC Corporation of America, ZSE30-N7L-65 Datasheet - Page 5

no-image

ZSE30-N7L-65

Manufacturer Part Number
ZSE30-N7L-65
Description
SENSOR VACUUM 100KPA 1-TOUCH PNP
Manufacturer
SMC Corporation of America
Series
ZSE30r
Datasheet

Specifications of ZSE30-N7L-65

Pressure Type
Vacuum
Operating Pressure
±14.5 PSI, ±100 kPa
Port Size
Male, 1/4" (6.35mm) One Touch
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Surface Mount
Operating Temperature
0°C ~ 50°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
606-1008
Setting
Function setting
16-2-8
Series
Display calibration
Peak/Bottom hold function
Press the SET button to return to the normal measuring mode.
During measuring mode, press the SET and
simultaneously and hold for 2 seconds or longer.
current measured value will be displayed.
Press the
there is no button operation for more than 2 seconds after
changing the set value, the display mode returns to displaying
Press the SET button to display the adjusted value (percent).
The adjusted value and
This function eliminates slight differences in the output values and
allows uniformity in the numbers displayed.
Displayed values of the pressure sensor can be calibrated to within
±5% for Series ISE and ±2.5% for Series ZSE.
Note) When the display calibration function is used, the regulating pressure
This function constantly detects and updates the maximum
and minimum pressure values and allows to hold the display
value.
To use a peak hold function, press and hold the
for 1 second or longer. The maximum pressure value is held
and blinks repeatedly. Press and hold the
for 1 second or longer to release this function and return to
the measuring mode.
To use a bottom hold function, press the
second or longer. The minimum pressure value is held and
blinks repeatedly. Press and hold
second or longer to release this function and return to the
measuring mode.
value may change ±1 digit.
and the current measured value.
OUT
OUT
PRESSURE
PRESSURE
(±2.5% R.D.)
ZSE30/ISE30
UP or
±5% R.D.
0 Applied pressure
DOWN button to change the set value. If
OUT
Alternately
Alternately
displayed
displayed
+
PRESSURE
will be alternately displayed.
DOWN button again for 1
: Factory setting display value
: Display calibration range
Current measured value
set prior to shipment
OUT
OUT
Adjusted value
DOWN button for 1
(Percent)
UP button again
PRESSURE
PRESSURE
DOWN buttons
UP button
and
Key lock function
Zero out (Zero ADJ) function
This function prevents incorrect operations such as changing
the set value accidentally. Press the SET button and hold for 4
seconds or longer to display the current
Press the
this function with the SET button. Use the
accidental button operation. To release a key lock function,
press the SET button and hold for 4 seconds or longer to
display the current setting, and select the
Unit Conversion Function
When not selecting “M” for unit specification
Desired display unit can be selected.
Press the
the set value is automatically converted.
The conversion order is: PA⇔GF⇔bAr⇔PSi⇔inH⇔mmH
Press the SET button to set the unit and proceed to the
display color setting.
This function clears and resets the displayed value as long as
the measuring pressure is within ±70 digits of the atmospheric
pressure.
(Due to individual product differences, the setting range varies
±10% F.S.)
This function is effective in detecting pressure fluctuations that
exceed a certain amount without being affected by the supply
pressure. Press and hold the
simultaneously to reset the display. Release the buttons to
return to the measuring mode.
Indication of Units
For vacuum/low pressure
For positive pressure
Displayed unit
Pa
kgf/cm
bar
psi
mmHg
inchHg
Press the
and hold for 4 sec.
or longer
Press and hold for
1 second or longer.
2
+
UP or
UP or
SET
button
Lock
DOWN button to select the setting and set
DOWN button to switch the unit, and
Selection of lock and unlock
Pa⇔kgf/cm
MPa⇔kgf/cm
0.001 MPa
ISE30
0.01
0.01
0.2
2
⇔bar⇔psi⇔inchHg⇔mmHg
UP and
2
⇔bar⇔psi
Unlock
DOWN buttons
mode.
or
mode to avoid
0.2 kPa
ZSE30
0.002
0.002
0.05
0.2
2
SET
setting.