SCXL004DN Honeywell Sensing and Control, SCXL004DN Datasheet - Page 3

SENSOR TEMP COMP 4"H2O

SCXL004DN

Manufacturer Part Number
SCXL004DN
Description
SENSOR TEMP COMP 4"H2O
Manufacturer
Honeywell Sensing and Control
Series
SCXLr
Datasheets

Specifications of SCXL004DN

Pressure Type
Differential
Operating Pressure
0.14 PSI, 4" H20
Port Size
Male, 0.19" (4.8mm) Tube, Dual
Output
0 ~ 40mV
Voltage - Supply
18V
Termination Style
Surface Mount
Operating Temperature
0°C ~ 70°C
Package / Case
6-SIP
Sensor Output
Voltage
External Depth
27mm
Voltage Rating
18V
Port Style
Straight
Pressure Measurement Type
Differential, Gage
Operating Pressure Range
0-4" H2O
No. Of Ports
1
Terminal Type
PCB
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
287-1027
Microstructure Pressure Sensors
Precision Compensated
0 in H
SCXL010DN PERFORMANCE CHARACTERISTICS
Characteristic
Zero Pressure Offset
Sensitivity
Combined Pressure Non-Linearity and Pressure Hysteresis
Temperature Effect on Span 0 °C to 50 °C [32 °F to 122 °F]
Temperature Effect on Offset 0 °C to 50 °C [32 °F to 122 °F]
Repeatability
Input Resistance
Output Resistance
Common Mode Voltage
Response Time
Long Term Stability of Offset and Span
SPECIFICATION NOTES
Note 1:
Note 2:
Note 3:
Note 4:
Note 5:
Note 6:
Note 7:
Note 8:
Note 9:
Note 10:
Note 11:
Note 12:
ORDERING INFORMATION
Description
0 in H
0 in H
Special Options: Pins with N-90 = 90° Lead Bend
ELECTRICAL CONNECTION
Pinout
2
2
O to 4 in H
O to 10 in H
2
Full-Scale Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure.
Full-Scale Span is ratiometric to the supply voltage.
Proof pressure is the pressure above which devices will not return to guaranteed specifications.
Reference Conditions: (Unless otherwise noted)
T
pressure is applied to Port A, and the output polarity is reversed.
Zero pressure effect is measured with pins pointed towards the ground. Offset can be position sensitive.
Pressure Hysteresis – the maximum output difference at any point within the operating pressure range for increasing and
decreasing pressure.
Maximum error band of the offset voltage and the error band of the span, relative to the 25 °C [77 F] reading.
Maximum difference in output at any pressure within the operating pressure range and the temperature within 0 °C to 50 °C
[32 F to 122 F] after:
004DN: a) 100 temperature cycles, 0 °C to 50 °C [32 F to 122 F]
010DN: a) 1,000 temperature cycles, 0 °C to 50 °C [32 F to 122 F]
Input resistance is the resistance between pins 2 and 4.
Output resistance is the resistance between pins 3 and 5.
Common Mode voltage of the output arms (Pins 3 and 5) for V
Response time for a 0 psi to Full-Scale Span pressure step change, 10 % to 90 % rise time.
Long term stability over a one-year period.
O to 4 in H
A
= 25 °C, Supply V
(7)
(11)
(8)
2
b) 1 million pressure cycles, 0 psi to Full-Scale Span.
b) 1.5 million pressure cycles, 0 psi to Full-Scale Span.
O
2
(9)
O
(4)
(10)
2
S
O and 0 in H
= 12 Vdc, Common Mode Line pressure = 0 psig, Pressure applied to Port B. For absolute devices only,
SCXL004DN [0 in H
PIN 2) V
PIN 3) + Output
PIN 4) Ground
PIN 5) - Output
PIN 6) Temperature output (-)
PIN 1) Temperature output (+)
(12)
s
SCXL 004DN
SCXL 010DN
2
O to 10 in H
2
O to 4 in H
Part Number
(6)
(5)
(3)
(6)
2
O]
S
=12 Vdc.
2
O
Min.
-0.3
5.8
SCXL004DN [0 in H
PIN 2) V
PIN 3) + Output
PIN 4) Ground
PIN 5) - Output
PIN 6) No Connection
PIN 1) No Connection
0.0
2
±0.2
±0.2
±300
±0.2
4.0
4.0
6.0
100
100
Typ.
Honeywell • Sensing and Control 3
Max.
0.3
±0.5
±1.0
±500
±0.5
6.2
s
mV
mV/in H
% FSS
% FSS
Microvolts
% FSS
kOhm
kOhm
Vdc
Microsec.
Microvolts
SCXL Series
2
O to 10 in H
Unit
2
O
2
O]

Related parts for SCXL004DN