24PCAFA6D Honeywell Sensing and Control, 24PCAFA6D Datasheet - Page 3
24PCAFA6D
Manufacturer Part Number
24PCAFA6D
Description
SENSOR 1PSI DIFFERENTIAL GAGE
Manufacturer
Honeywell Sensing and Control
Series
24PCr
Specifications of 24PCAFA6D
Pressure Type
Differential
Operating Pressure
1 PSI
Output
0 ~ 45mV
Voltage - Supply
10V
Termination Style
Cable 2'
Operating Temperature
-40°C ~ 85°C
Package / Case
4-SIP, Dual Ports, Opposite Sides
Sensor Output
Voltage
External Depth
1.35"
Voltage Rating
10V
Port Style
Straight
Pressure Measurement Type
Differential
Mounting Type
Through Hole
Terminal Type
PCB Thru Hole
Output Type
Voltage
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
480-2496
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Ultra-low
Pressure Sensors
Signal conditioning
Pressure range
Device type
Output
Calibrated
Temperature compensated
Operating temperature range
Accuracy
Mounting options
Ultra-low
Pressure Sensors
Signal conditioning
Pressure range
Device type
Output
Calibrated
Temperature compensated
Operating temperature range
Accuracy
Mounting options
DCXl-DS
unamplified
±1 in H
differential
mV
yes
yes
0 °C to 50 °C
[32 °F to 122 °F]
linearity & hysteresis
0.2% typ.
SIP
XPCl Series
unamplified
4 in H
differential, gage
mV
yes
yes
0 °C to 70 °C [32 °F to 158 °F] (compensated)
linearity & hysteresis
0.5% typ.
SIP
2
O to 10 in H
2
O to ±10 in H
2
O
2
O
XCAl Series
amplified
±4 in H
differential
Vdc
yes
yes
0 °C to 50 °C
[32 °F to 122 °F] (compensated)
-
SIP
2
O to ±10 in H
2
XPXl Series
unamplified
4 in H
differential, gage
mV
no
no
-25 °C to 85 °C [-13 °F to 185 °F]
linearity & hysteresis
0.5% typ.
SIP
O
2
O to 10 in H
www.honeywell.com/sensing
2
O
XCXl Series
unamplified
±4 in H
differential
mV
yes
yes
0 °C to 70 °C
[32 °F to 158 °F] (compensated)
linearity & hysteresis
0.5% typ.
SIP
2
O to ±10 in H
2
O
3