CM200DY-34A Powerex Inc, CM200DY-34A Datasheet

IGBT MOD DUAL 1700V 200A A SER

CM200DY-34A

Manufacturer Part Number
CM200DY-34A
Description
IGBT MOD DUAL 1700V 200A A SER
Manufacturer
Powerex Inc
Series
IGBTMOD™r
Type
IGBT Moduler
Datasheet

Specifications of CM200DY-34A

Configuration
Half Bridge
Voltage - Collector Emitter Breakdown (max)
1700V
Vce(on) (max) @ Vge, Ic
2.8V @ 15V, 200A
Current - Collector (ic) (max)
200A
Current - Collector Cutoff (max)
1mA
Input Capacitance (cies) @ Vce
49.4nF @ 10V
Power - Max
1980W
Input
Standard
Ntc Thermistor
No
Mounting Type
Chassis Mount
Package / Case
Module
Module Configuration
Dual
Transistor Polarity
N Channel
Dc Collector Current
200A
Collector Emitter Voltage Vces
1.7kV
Power Dissipation Pd
1.98kW
Operating Temperature Range
-40°C To +150°C
Distributorinventory
View
Voltage
1700V
Current
200A
Circuit Configuration
Dual
Rohs Compliant
Yes
Recommended Gate Driver
VLA500K-01R
Interface Circuit Ref Design
BG2A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
BG2B-5015 - KIT DEV BOARD 2CN 5A FOR IGBTBG2B-3015 - KIT DEV BOARD 2CN 3A FOR IGBTBG2B-1515 - KIT DEV BOARD 1.5A FOR IGBTBG2A-NF - KIT DEV BOARD FOR IGBT
Igbt Type
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CM200DY-34A
Manufacturer:
QUALCOMM
Quantity:
2 000
Part Number:
CM200DY-34A
Manufacturer:
MIT
Quantity:
20 000
Dimensions
01/10 Rev. 1
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272
www.pwrx.com
Outline Drawing and Circuit Diagram
C
D
G
H
M
A
B
E
F
K
L
1.18+0.04/-0.02 30.0+1.0/-0.5
C
C2E1
(4 PLACES)
B
3.66±0.01
M6 Metric
1.89±0.01
0.26 Dia.
Inches
4.25
2.44
0.98
0.24
0.59
0.55
E
V
N
L
Millimeters
93.0±0.25
48.0±0.25
W
Dia. 6.5
108.0
62.0
25.0
15.0
14.0
C2E1
M6
K
P
6.0
E2
Q
F
LABEL
E2
K
D
P
A
F
Q
Dimensions
C1
P
K
W
N
P
Q
R
S
U
V
X
T
X
G2
E2
E1
G1
C1
G2
E2
E1
G1
T THICK
U WIDTH
M NUTS
(3 PLACES)
Inches
0.71
0.28
0.87
0.33
0.02
0.110
0.16
0.85
0.94
1.18
S
R
G
G
H
Millimeters
30.0
22.2
24.0
18.0
21.5
8.5
0.5
2.8
4.0
7.0
CM200DY-34A
Dual IGBTMOD™
A-Series Module
200 Amperes/1700 Volts
Description:
Powerex IGBTMOD™ Modules
are designed for use in switching
applications. Each module
consists of two IGBT Transistors
in a half-bridge configuration with
each transistor having a reverse-
connected super-fast recovery
free-wheel diode. All components
and interconnects are isolated from
the heat sinking baseplate, offering
simplified system assembly and
thermal management.
Features:
£ Low Drive Power
£ Low V CE(sat)
£ Discrete Super-Fast Recovery
£ Isolated Baseplate for Easy
Applications:
£ AC Motor Control
£ UPS
£ Battery Powered Supplies
Ordering Information:
Example: Select the complete
part module number you
desire from the table below -i.e.
CM200DY-34A is a 1700V (V CES ),
200 Ampere Dual IGBTMOD™
Power Module.
Type
CM
Free-Wheel Diode
Heat Sinking
Current Rating
Amperes
200
Volts (x 50)
V CES
34
1

Related parts for CM200DY-34A

CM200DY-34A Summary of contents

Page 1

... AC Motor Control £ UPS £ Battery Powered Supplies Ordering Information: Example: Select the complete part module number you desire from the table below -i.e. CM200DY-34A is a 1700V (V CES ), 200 Ampere Dual IGBTMOD™ Power Module. Type Current Rating V CES Amperes ...

Page 2

... 200A 0V* Symbol Test Conditions C ies C oes 10V res t d(on 1000V 200A, t d(off) V GE1 = V GE2 = 15V 2.4Ω Inductive Load Switching Operation 200A Symbol CM200DY-34A T j –40 to 150 T stg –40 to 125 V CES 1700 V GES ± 200 Amperes I CM 400 Amperes 200 Amperes ...

Page 3

... Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com CM200DY-34A Dual IGBTMOD™ A-Series Module 200 Amperes/1700 Volts Thermal and Mechanical Characteristics 25°C unless otherwise specified Characteristics Thermal Resistance, Junction to Case Thermal Resistance, Junction to Case Contact Thermal Resistance External Gate Resistance *4 Case temperature ( and heatsink temperature ( measured point is just under the chips. *5 Typical value is measured by using thermally conductive grease of λ ...

Page 4

... Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com CM200DY-34A Dual IGBTMOD™ A-Series Module 200 Amperes/1700 Volts SWITCHING TIME VS. COLLECTOR CURRENT (TYPICAL d(off d(on 1000V 15V 2.4Ω 125°C j Inductive Load COLLECTOR CURRENT (AMPERES) C SWITCHING LOSS VS. ...

Related keywords