ATMEGA1284RZAP-MU Atmel, ATMEGA1284RZAP-MU Datasheet - Page 33

no-image

ATMEGA1284RZAP-MU

Manufacturer Part Number
ATMEGA1284RZAP-MU
Description
BUNDLE ATMEGA1284P/RF230 QFN
Manufacturer
Atmel
Datasheet

Specifications of ATMEGA1284RZAP-MU

Frequency
2.4GHz
Modulation Or Protocol
802.15.4 Zigbee, 6LoWPAN, ISM
Data Interface
PCB, Surface Mount
Memory Size
128kB Flash, 4kB EEPROM, 16kB RAM
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Package / Case
44-QFN, 32-QFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Supply
-
Power - Output
-
Applications
-
Sensitivity
-
Data Rate - Maximum
-
Current - Transmitting
-
Current - Receiving
-
2549MS–AVR–09/10
5. IN/OUT instructions may be executed twice when Stack is in external RAM
6. EEPROM read from application code does not work in Lock Bit Mode 3
- The actual value of the reference can be measured by applying a known voltage to the
ADC when using the internal reference. The result when doing later conversions can then be
calibrated.
If either an IN or an OUT instruction is executed directly before an interrupt occurs and the
stack pointer is located in external ram, the instruction will be executed twice. In some cases
this will cause a problem, for example:
- If reading SREG it will appear that the I-flag is cleared.
- If writing to the PIN registers, the port will toggle twice.
- If reading registers with interrupt flags, the flags will appear to be cleared.
Problem Fix/Workaround
There are two application workarounds, where selecting one of them, will be omitting the
issue:
- Replace IN and OUT with LD/LDS/LDD and ST/STS/STD instructions.
- Use internal RAM for stack pointer.
When the Memory Lock Bits LB2 and LB1 are programmed to mode 3, EEPROM read does
not work from the application code.
Problem Fix/Workaround
Do not set Lock Bit Protection Mode 3 when the application code needs to read from
EEPROM.
ATmega640/1280/1281/2560/2561
33

Related parts for ATMEGA1284RZAP-MU