EM2420-RTR Ember, EM2420-RTR Datasheet - Page 73
EM2420-RTR
Manufacturer Part Number
EM2420-RTR
Description
IC RF TXRX ZIGBEE 2.4GHZ 48-QLP
Manufacturer
Ember
Datasheet
1.EM2420-RTR.pdf
(84 pages)
Specifications of EM2420-RTR
Mfg Application Notes
EM2420
Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
-3dBm
Sensitivity
-94dBm
Voltage - Supply
2.1V ~ 3.6V
Current - Receiving
19.7mA
Current - Transmitting
17.4mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Package / Case
48-QLP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Other names
636-1006-2
Bit
AGCTST1 (0x25) - AGC Test Register 1
Bit
15
14
13
12:11
10:8
7:6
5:0
AGCTST2 (0x26) - AGC Test Register 2
Bit
15:10
9:5
4:0
Ember Part Number: 120-0049-000D
Field Name
Field Name
-
AGC_BLANK_MODE
PEAKDET_CUR_BOOST
AGC_SETTLE_WAIT[1:0]
AGC_PEAK_DET_MODE
[2:0]
AGC_WIN_SIZE[1:0]
AGC_REF[5:0]
Field Name
-
MED2HIGHGAIN[4:0]
LOW2MEDGAIN[4:0]
Reset
Reset
0
0
0
1
0
1
20
Reset
0
9
10
EM2420 Datasheet
R/W
R/W
W0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
W0
R/W
R/W
Description
gain mode, defined in 2 dB steps
Description
Reserved, write as 0
Set the VGA blanking mode when switching out a gainstage
When VGA_GAIN_OE = 0:
0 : Blanking is performed when the AGC algorithm switches
out one or more 14dB gain stages.
1 : Blanking is never performed.
When VGA_GAIN_OE = 1:
Blanking is performed when AGC_BLANK_MODE=1
Doubles the bias current in the peak-detectors in-between the
VGA stages when set.
Timing for AGC to wait for analog gain to settle.
Sets the AGC mode for use of the VGA peak detectors:
Bit 2 : Digital ADC peak detector enable / disable
Bit 1 : Analog fixed stages peak detector enable /
Bit 0 : Analog variable gain stage peak detector enable /
Window size for the accumulate and dump function in the
AGC.
0 : 8 samples
1 : 16 samples
2 : 32 samples
3 : 64 samples
Target value for the AGC control loop, given in 2 dB steps.
Reset value corresponds to approximately 25% of the ADC
dynamic range in reception.
Description
Reserved, write as 0
MED2HIGHGAIN sets the difference in the receiver
LNA/MIXER gain from medium gain mode to high gain mode,
used by the AGC for setting the correct frontend gain mode.
LOW2MEDGAIN sets the difference in the receiver
LNA/MIXER gain from low gain mode to medium gain mode,
used by the AGC for setting the correct frontend gain mode.
disable
disable
EM2420
Page 73 of 84