LMX9838SB/NOPB National Semiconductor, LMX9838SB/NOPB Datasheet - Page 5

IC MODULE BLUETOOTH PORT 70LTCC

LMX9838SB/NOPB

Manufacturer Part Number
LMX9838SB/NOPB
Description
IC MODULE BLUETOOTH PORT 70LTCC
Manufacturer
National Semiconductor
Datasheet

Specifications of LMX9838SB/NOPB

Frequency
2.4GHz
Data Rate - Maximum
704kbps
Modulation Or Protocol
Bluetooth v2.0, Class 2
Applications
PDA's, POS Terminals
Power - Output
0dBm
Sensitivity
-80dBm
Voltage - Supply
2.5 V ~ 3.6 V
Current - Receiving
65mA
Current - Transmitting
65mA
Data Interface
PCB, Surface Mount
Antenna Connector
On-Board, Chip
Operating Temperature
-40°C ~ 125°C
Package / Case
70-LTCC
Physical Interfaces
UART
Data Rate
704Kbps
Operating Temperature Range
-40°C To +85°C
Msl
MSL 4 - 72 Hours
Frequency Max
2480MHz
Filter Terminals
SMD
Frequency Min
2402MHz
No. Of Pins
70
Rohs Compliant
Yes
For Use With
LMX9838DONGLE - KIT DESIGN DONGLE FOR LMX9838
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / Rohs Status
Compliant
Other names
LMX9838SB

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LMX9838SB/NOPB
Manufacturer:
NSC
Quantity:
560
Part Number:
LMX9838SB/NOPB
Manufacturer:
TI/德州仪器
Quantity:
20 000
9.0 Application Diagrams
The following diagrams show two application examples for
LMX9838 implementations.
Figure 1 illustrates a cable replacement application, requiring
the physical UART interface to a data device like a sensor.
The LMX9838 just waits for an incoming link and forwards
data between the data device and the bluetooth link. PG6 acts
as active link indicator and is used to enable the data transfer
from the sensor. A 32.768khz crystal may be is used to reduce
power consumption while waiting for the incoming link.
FIGURE 2. Example For Host Controller Based Application With Audio Support
FIGURE 1. Example For A Cable Replacement Application
5
Figure 2 shows an example for the connection to a host con-
troller, which can include a simple application to control the
LMX9838. The figure also includes the connection to a PCM
codec, in case the host controller application includes an au-
dio profile. Reset, OP4 and OP5 are controlled by the host for
full control of the LMX9838 status.
Please refer to Section 17.0 Application Notes for more de-
tailed descriptions for LMX9838 designs.