XT09-MI Digi International/Maxstream, XT09-MI Datasheet - Page 28

no-image

XT09-MI

Manufacturer Part Number
XT09-MI
Description
MODULE RF 900MHZ 1W 115K W/MMCX
Manufacturer
Digi International/Maxstream
Datasheets

Specifications of XT09-MI

Frequency
900MHz
Modulation Or Protocol
FHSS, FSK
Power - Output
1W
Sensitivity
-100dBm
Voltage - Supply
2.8 V ~ 5.5 V
Current - Receiving
80mA
Antenna Connector
MMCX
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS non-compliant
Applications
-
Memory Size
-
Data Interface
-
Data Rate - Maximum
-
Current - Transmitting
-
9XTend™ OEM RF Module ‐ Product Manual v2.x4x [2007.01.04]
HP (Hopping Channel) Command
HT (Time before Wake-up Initializer) Command
HV (Hardware Version) Command
ID (Modem VID) Command
<Networking & Security> The HP command is
used to set/read the RF module's hopping channel
number. A channel is one of three layers of filtra-
tion available to the module.
In order for modules to communicate with each
other, the modules must have the same channel
number since each channel uses a different hop-
ping sequence. Different channels can be used to
prevent modules in one network from listening to
transmissions of another.
<Sleep (Low Power)> The HT command is used
to set/read the time of inactivity (no serial or RF
data is sent or received) before a wake-up initial-
izer is sent by a TX (transmitting) RF module. The
HT parameter should be set shorter than inactiv-
ity timeout [ST Command] time of any RX
(receiving) modules operating in Cyclic Sleep
(SM=4-8). The wake-up initializer sent by the TX
module instructs all RX modules to remain awake
to receive RF data.
From the RX module perspective: After HT time
elapses and the inactivity timeout [ST Command]
is met, the RX module goes into cyclic sleep. In cyclic sleep, the RX module wakes once per sleep
interval [SM Command] to check for a wake-up initializer. When a wake-up initializer is detected,
the module stays awake to receive data. The wake-up initializer must be longer than the cyclic
sleep interval to ensure that sleeping modules detect incoming data.
When HT time elapses, the TX module knows it needs to send a wake-up Initializer for all RX mod-
ules to remain awake and receive the next transmission.
<Diagnostics> The HV command is used to read
the hardware version of the RF module.
<Networking & Security> The ID command is
used to set/read the VID (Vendor Identification
Number) of the RF module. RF modules must
have matching VIDs in order to communicate.
© 2007 MaxStream, Inc.
AT Command: ATHT
Binary Command: 0x03 (3 decimal)
Parameter Range: 0 - 0xFFFF
Default Parameter Value: 0xFFFF (wake-up
initializer will not be sent)
Number of bytes returned: 2
Related Commands: LH (Wake-up Initializer
Timer), SM (Sleep Mode), ST (Time before
Sleep)
AT Command: ATHV
Parameter Range: 0 - 0xFFFF [Read-only]
Minimum Firmware Version Required: v1.x80
AT Command: ATID
Binary Command: 0x27 (39 decimal)
Parameter Range:
Default Parameter Value: 0x3332 (13106d)
Number of bytes returned: 2
AT Command: ATHP
Binary Command: 0x11 (17 decimal)
Parameter Range: 0 - 9
Default Parameter Value: 0
Number of bytes returned: 1
Related Commands: ID (Modem VID), DT
(Destination Address), MK (Address Mask)
0x11 - 0x7FFF (user-settable)
0 - 0x10 & 0x8000 - 0xFFFF (factory-set)
Chapter 3 ‐ RF Module Configuration
[x 100 milliseconds]
     28

Related parts for XT09-MI