RN-42 Roving Networks Inc, RN-42 Datasheet - Page 9

MODULE BLUETOOTH V2.1+EDR

RN-42

Manufacturer Part Number
RN-42
Description
MODULE BLUETOOTH V2.1+EDR
Manufacturer
Roving Networks Inc
Series
RNr
Datasheets

Specifications of RN-42

Frequency
2.4GHz
Data Rate - Maximum
3Mbps
Modulation Or Protocol
Bluetooth v2.1+EDR, Class 2 & 3
Applications
General Purpose
Power - Output
2dBm
Sensitivity
-80dBm
Voltage - Supply
3 V ~ 3.6 V
Current - Receiving
25mA
Current - Transmitting
25mA
Data Interface
PCB, Surface Mount
Antenna Connector
On-Board, Chip
Operating Temperature
-40°C ~ 85°C
Package / Case
Packaged Unit
Wireless Frequency
2.4 GHz
Data Rate
1200 bps to 921 Kbps
Modulation
FHSS, GFSK
Operating Voltage
3.3 V
Antenna
Chip
Operating Temperature Range
- 40 C to + 85 C
Output Power
2 dBm
Technology/ Type
Class 2 Bluetooth Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
740-1038

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RN-42-EK
Manufacturer:
CONEXANT
Quantity:
320
Part Number:
RN-42-SM
Manufacturer:
MICROCHIP
Quantity:
101
www.rovingnetworks.com
SE,<1,0>
SF,1
SI, <hex word> -
SJ, <hex word>
SL,<E,O,N>
SM,<5,4,3,2,1,0>
SN,<name>
S-,<name>
SO,<text>
809 University Avenue
SC,001F
SD,0123
Inquiry Scan Window. Sets amount of time device spends enabling inquiry scan
(discoverability). Minimum value is 0x0012, corresponding to about 1% duty cycle.
Inquiry interval is fixed at 0x800, so time spent in inquiry is 0x12/0x100 by default.
Maximum value is 0x800, set to 0x0000 to disable inquiry scan and make device non-
discoverable. Default value is 0x0200.
Page Scan Window. Sets amount of time device spends enabling page scan
Encryption 1 to enable, 0 to disable.
Set Factory Defaults.
(connectability) . Minimum value is 0x0012, corresponding to about 1% duty cycle.
Page Scan interval is fixed at 0x800, so time spent in page scan mode is 0x12/0x800
by default. Maximum value is 0x800, set to 0x0000 to disable page scan and make
device non-connectable. Default value is 0x0200.
Set UART parity.
needed and must be capital.
Example : “SL,E”
Mode (0=slave, 1=master,2=trigger, 3=auto, 4=DTR, 5=ANY)
Example : “SM,1”
Name of the device, 20 characters maximum.
Example: “SN,MyDevice”
Serialized Friendly Name of the device, 15 characters maximum.
This command will automatically append the last 2 bytes of the BT MAC address to
the name. Useful for generating a custom name with unique numbering.
Example: S-,MyDevice
Extended Status String, 8 character maximum. Setting this string to from 1 to 8
characters will enable status messages to be sent to the local serial port. Two status
messages are sent, when a Bluetooth connection is established, the string
”<text>CONNECT” will be sent. Upon a Disconnect, the string
<text>DISCONNECT will be sent. This parameter is useful, for example, when
connected to a printer, the printer can examine an escape sequence, if the <text> is
set to ESC%, the printer can parse the ESC%CONNECT and ESC%DISCONNECT
messages without interfering with normal print jobs. In Trigger or Master modes, the
first character of this string is used as the BREAK connection character.
Example: SO,ESC%
Los Gatos, CA 95032
Can be any of, Even, Odd, or None. Only the first character is
~ 9 ~
Tel (408) 395-6539
will set the name to “MyDevice-ABCD”
rn-bluetooth-um Version 4.77 1/24/2011
sets the mode to Master
sets the parity to Even.
Advanced User Manual
• info@RovingNetworks.com