CL4490-1000-PRO Laird Technologies, CL4490-1000-PRO Datasheet - Page 19

TXRX 900MHZ PRO 1W W/ANT DB9

CL4490-1000-PRO

Manufacturer Part Number
CL4490-1000-PRO
Description
TXRX 900MHZ PRO 1W W/ANT DB9
Manufacturer
Laird Technologies
Series
Connexlink™r
Datasheet

Specifications of CL4490-1000-PRO

Function
Transceiver
Modulation Or Protocol
FHSS, FSK
Frequency
902MHz ~ 928MHz
Applications
General Purpose
Interface
RS-232
Sensitivity
-99dBm
Power - Output
1000mW
Data Rate - Maximum
76.8 kbps
Features
450m Range
Voltage - Supply
7 V ~ 18 V
Package / Case
Module
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
CL4490 User’s Manual
4.2.2 CN4490 Settings
The CN4490 Settings Page is shown below, as it will appear the first time when the CN4490
check box is checked.
4.2.2.1 CN4490 Settings
Client/Server: Designates CN4490 type. In each network, there must be only one Server. All
other CN4490 units must be programmed as Clients. The number of Clients in the network is not
limited; however, if performance diminishes, consider additional RF Networks.
Channel Number: A number that designates an independent network of CN4490 units. Up to
32 independent networks can be created. The valid range of values for this field is 16 to 47.
Max Transmit Retries (For Clients and Servers in Point-to-Point networks only): This value
represents the maximum number of times a particular data packet will be transmitted
unsuccessfully, or without an acknowledgement, before the CN4490 discards the packet. The
default value is 16 attempts. If communication is lost and the Client’s Link LED is on, try
increasing this value in small increments until communication is reestablished.
Note: This value is always associated to Client radios and Server radios in Point to Point Mode.
The valid range of values for this field is 2 to 255.
10/3/2005
19