X24-009PKC-UA Digi International/Maxstream, X24-009PKC-UA Datasheet - Page 21

no-image

X24-009PKC-UA

Manufacturer Part Number
X24-009PKC-UA
Description
MODEM RF 2.4GHZ 9600BPS USB
Manufacturer
Digi International/Maxstream
Series
XStream™r
Datasheets

Specifications of X24-009PKC-UA

Function
Transceiver, Modem
Modulation Or Protocol
FHSS
Frequency
2.4GHz ~ 2.4835GHz
Applications
General Purpose
Interface
USB
Sensitivity
-110dBm
Power - Output
17dBm (50mW)
Data Rate - Maximum
20 kbps
Voltage - Supply
5V
Package / Case
Module
Lead Free Status / RoHS Status
Request inventory verification / Request inventory verification
Features
-
XStream‐PKG‐U™ USB RF Modem – Product Manual v4.2B5 [2006.02.27] 
CT (Command Mode Timeout) Command
DT (Destination Address) Command
E0 (Echo Off) Command
E1 (Echo On) Command
ER (Receive Error Count) Command
FH (Force Wake-up Initializer) Command
<Command Mode Options> CT Command sets
the amount of time before AT Command Mode
terminates automatically. After a CT time of
inactivity, the modem exits AT Command Mode
and returns to Idle Mode. AT Command Mode can
also be exited manually using CN (Exit AT
Command Mode) Command.
<Networking> DT Command is used to set the
networking address of an XStream Modem.
XStream Modems uses three network layers –
Vendor Identification Number (ATID), Channels
(ATHP), and Destination Addresses (ATDT). DT
Command assigns an address to a modem that
enables it to communicate only with other
modems having the same addresses. All modems
that share the same Destination Address can communicate freely with each other. Modems in the
same network with a different Destination Address (than that of the transmitter) will listen to all
transmissions to stay synchronized, but will not send any of the data out their serial ports.
<Command Mode Options> E0 Command turns
off character echo in AT Command Mode. By
default, echo is off.
<Command Mode Options> E1 Command turns
on the echo in AT Command Mode. Each typed
character will be echoed back to the terminal
when ATE1 is active. E0 is the default.
<Diagnostics> Set/Read the receive-error. The
error-count records the number of packets
partially received then aborted on a reception
error. This value returns to 0 after a reset and is
not non-volatile (Value does not persist in the
modem’s memory after a power-up sequence).
Once the “Receive Error Count” reaches its
maximum value (up to 0xFFFF), it remains at its maximum count value until the maximum count
value is explicitly changed or the modem is reset.
<Sleep (Low Power)> FH Command is used to
force a Wake-up Initializer to be sent on the next
transmit. WR (Write) Command does not need to
be issued with FH Command.
Use only with cyclic sleep modes active on remote modems.
   © 2006 MaxStream, Inc. Confidential and Proprietary 
AT Command: ATCT
Binary Command: 0x06 (6 decimal)
Parameter Range: 0x02 – 0xFFFF
Default Parameter Value: 0xC8 (200 decimal,
20 seconds)
Number of bytes returned: 2
AT Command: ATDT
Binary Command: 0x00
Parameter Range: 0 – 0xFFFF
Default Parameter Value: 0
Number of bytes returned: 2
Related Commands: HP (Hopping Channel), ID
(Modem VID), MK (Address Mask)
AT Command: ATE0
Binary Command: 0x0A (10 decimal)
AT Command: ATE1
Binary Command: 0x0B (11 decimal)
AT Command: ATER
Binary Command: 0x0F (15 decimal)
Parameter Range: 0 – 0xFFFF
Default Parameter Value: 0
Number of bytes returned: 2
Related Commands: GD (Receive Good Count)
AT Command: ATFH
Binary Command: 0x0D (13 decimal)
[x 100 milliseconds]
21 

Related parts for X24-009PKC-UA