UGWKEC9VEA1-EK Unigen Corp, UGWKEC9VEA1-EK Datasheet - Page 24

EVALUATION KIT ECHO 900

UGWKEC9VEA1-EK

Manufacturer Part Number
UGWKEC9VEA1-EK
Description
EVALUATION KIT ECHO 900
Manufacturer
Unigen Corp
Series
Echor
Type
Transceiver, UHFr
Datasheets

Specifications of UGWKEC9VEA1-EK

For Use With/related Products
Echo 900
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
784-1034
Solutions for a Real Time World
ADParam
Re-Tek - 1533
94539
support@unigen.com
http://www.unigen.com
ADParam_enable_konn
ADParam_disable_data
ADParam_Chge_thres
ADParam_Sync_thres 6-0
ADParam_Trac_thres
ADParam_Sync_loss
ADParam_Fix_bsync
ADParam_Regcond
ADParam_Resxosc
ADParam_Clk_freq
ADParam_RegBW
ADParam_Regfreq
ADParam_Invert
ADParam_Psize
ADParam_Xsel
ADParam_Ptol
Name
_bidir
ex
Bits Address Description
5-4
3-2
4-1
6-0
6-0
7-6
1
0
7
6
5
0
7
7
7
PAN 433/868/902 MHz - UGW3S
01110 Size of reference pattern recognition word: 0 0 -> 8 bits 0 1 -
01110 Number of tolerated errors for the pattern recognition: 00 ->
01110 CLKOUT frequency (if enabled) 00 -> 1.22 MHz (div ratio
01110 Inversion of Rx output data: 0 -> disabled 1 -> enabled
01110 Baseband filter bandwidth calibration: 0 -> enabled 1 ->
01111 Period of baseband filter bandwidth calibration whilst Rx
01111 Baseband filter bandwidth calibration as a function of
01111 Selection of the XOSC load capacitance mode: 0 -> CL+C0
01111 Selection of the value of the shunt resistor across ports
01111 Konnex mode: 0 -> disabled 1 -> enabled
10000
10000 Barker mode sync acquisition threshold
10001 DATA port bidirectional mode: 0 -> enabled 1 -> disabled:
10001 Threshold for tracking Barker mode
10010 bit synchronizer configuration: 0-> default configuration 1->
10010 Number of bits before sync loss detection for Barker
Copyright Unigen Corporation, 2008
> 16 bits 1 0 -> 24 bits 1 1 -> 32 bits
0 error 01 -> 1 error 10 -> 2 errors 11 -> 3 errors
:32) 01 -> 2.44 MHz (div ratio :16) 10 -> 4.87 MHz (div ratio
:8) 11 -> 9.75 MHz (div ratio :4)
disabled
enabled: 0 -> only at start-up of the receiver 1 -> 60
seconds (default mode) or 7 seconds (test mode)
selected bandwidth: 0 -> calibration restarted each time the
bandwidth is changed 1 -> no calibration when the
bandwidth is changed
= 15 pF 1 -> CL+C0 = 11 pF, low current mode
TKA and TKB for a third overtone XTAL operation: 0000 ->
3800 kΩ 0001 -> 2.55 kΩ 0010 -> 4.65 kΩ 0011 -> 1.78 kΩ
0100 -> 8.79 kΩ 0101 -> 2.07 kΩ 0110 -> 3.22 kΩ 0111 ->
1.56 kΩ 1000 -> 16.55 kΩ 100
Enable programming of the sync and acquisition
thresholds: 0 -> threshold are hard-coded and sync-loss
counter is 50 bits 1 -> threshold are defined by
BParam_Sync_thres and BParam_Trac_thres Sync loss
counter is variable and defined by ADParam_Sync_loss
DATA = output, DATAIN = input
high-interference environment
decoding algorithm
ADParam
- 24 -
TEL: (510) 668.2088 FAX: (510) 661.2788
Customer Comment Line: (800) 826.0808
45388 Warm Springs Blvd. Fremont, CA
Datasheet

Related parts for UGWKEC9VEA1-EK