A24-HABUF-P5I Digi International/Maxstream, A24-HABUF-P5I Datasheet - Page 25

no-image

A24-HABUF-P5I

Manufacturer Part Number
A24-HABUF-P5I
Description
2.4GHZ ANTENNA U.FL
Manufacturer
Digi International/Maxstream
Datasheet

Specifications of A24-HABUF-P5I

Antenna Type
Whip
Number Of Bands
1
Frequency
2.4GHz
Gain
2.1dBi
Termination
U.FL
Mounting Type
Bulkhead
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Vswr
-
Height (max)
-
Other names
A24-HABUF-P51
A24-HABUF-P51
Q3655966F

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
A24-HABUF-P5I
Manufacturer:
MXS
Quantity:
36
XBee®/XBee‐PRO®  RF Modules ‐ 802.15.4 ‐ v1.xEx [2009.09.23]
Command Mode
AT Command Mode
To modify or read RF Module parameters, the module must first enter into Command Mode - a
state in which incoming characters are interpreted as commands. Two Command Mode options are
supported: AT Command Mode [refer to section below] and API Command Mode [p57].
To Enter AT Command Mode:
Default AT Command Mode Sequence (for transition to Command Mode):
All of the parameter values in the sequence can be modified to reflect user preferences.
NOTE: Failure to enter AT Command Mode is most commonly due to baud rate mismatch. Ensure the
‘Baud’ setting on the “PC Settings” tab matches the interface data rate of the RF module. By default,
the BD parameter = 3 (9600 bps).
To Send AT Commands:
Figure 2‐08. Syntax for sending AT Commands 
To read a parameter value stored in the RF module’s register, omit the parameter field.
The preceding example would change the RF module Destination Address (Low) to “0x1F”. To store
the new value to non-volatile (long term) memory, subsequently send the WR (Write) command.
For modified parameter values to persist in the module’s registry after a reset, changes must be saved
to non-volatile memory using the WR (Write) Command. Otherwise, parameters are restored to previ-
ously saved values after the module is reset.
System Response. When a command is sent to the module, the module will parse and execute
the command. Upon successful execution of a command, the module returns an “OK” message. If
execution of a command results in an error, the module returns an “ERROR” message.
To Exit AT Command Mode:
For an example of programming the RF module using AT Commands and descriptions of each config-
urable parameter, refer to the RF Module Configuration chapter [p26].
Send the 3-character command sequence “+++” and observe guard times before and after the
command characters. [Refer to the “Default AT Command Mode Sequence” below.]
Send AT commands and parameters using the syntax shown below.
1.
2.
© 2009 Digi Internatonal, Inc.
• No characters sent for one second [GT (Guard Times) parameter = 0x3E8]
• Input three plus characters (“+++”) within one second [CC (Command Sequence Character)
• No characters sent for one second [GT (Guard Times) parameter = 0x3E8]
parameter = 0x2B.]
Timeout) Command, the RF module automatically returns to Idle Mode.
Send the ATCN (Exit Command Mode) command (followed by a carriage return).
If no valid AT Commands are received within the time specified by CT (Command Mode
[OR]
     25

Related parts for A24-HABUF-P5I